8440-1770 | PCM1-M-I5-U4-P02 | 8440-2088 | easYgen-3500XT-P2 | | | |
5448-879 | GCP-2015B | 8440-2281 | easYgen-3200XT-P1-LITE | | | |
5448-883 | MFR1205B/CP | | | Independent time-overcurrent, Ground fault calculated - feature in easYgen-3000XT included; otherwise contact SEG Electronics for MRI3 | | |
5448-884 | MFR1110B/MP | 8441-1160 | easYprotec-1410-1 | no display or HMI in replacement | | |
5448-885 | MFR1110B/G59 | 8441-1160 | easYprotec-1410-1 | no display or HMI in replacement | | |
5448-886 | MFR1315B/GP | | | consider an easYgen control and consolidate functionality like Sychronization & Loadsharinig | | |
5448-890 | SPM-D1010B | 8440-2166 | SPM-D2-1010B | | | |
5448-893 | SPM-D1010B/X | 8440-2168 | SPM-D2-1010B/X | | | |
5448-895 | GW4B/RS232+MOD | | | Similar item GCP-MG from ProconX | | |
5448-897 | ESDR405TB | | | contact SEG Electronics for MRDT4-2A0AA | | |
5448-898 | MFR1315B/GPX | | | consider an easYgen control and consolidate functionality like Sychronization & Loadsharinig | | |
5448-899 | MFR1515B/SY | 8440-2082 | easYgen-3200XT | different load shareline! Load share Gateway LSG | | |
5448-901 | GW4B/RS485+MOD | | | Similar item GCP-MG from ProconX | | |
5448-902 | GW4B/PROFIBUS+DPSLAVE | 8445-1046 | ESEPRO | | | |
5448-906 | SPM-D1010B/YB | 8440-2167 | SPM-D2-1010B/YB | | | |
5448-909 | UMT115B/A3 | | | sorry, there is no direct replacement available | | |
5448-910 | GW4B/RS232+LDP | | | sorry, there is no direct replacement available | | |
5448-913 | GCP-2245B/LSR | 8440-2082 | easYgen-3200XT | | | |
5448-914 | GCP-2245B/LS | 8440-2082 | easYgen-3200XT | | | |
5448-915 | GCP-2145B/LSR | 8440-2082 | easYgen-3200XT | | | |
5448-916 | GCP-2145B/LS | 8440-2082 | easYgen-3200XT | | | |
5448-918 | GCP-2045B/LS | 8440-2082 | easYgen-3200XT | | | |
8406-020 | EGCP-1, 24VDC, 90-277 VAC PT'S | 8440-2082 | easYgen-3200XT | Loadshare Gateway LSG required if n+1 gens | | |
8406-021 | EGCP-1, 24VDC, 90-277 VAC PT'S | 8440-2082 | easYgen-3200XT | Loadshare Gateway LSG required if n+1 gens | | |
8406-113 | EGCP-3 'I LS" | 8440-2088 | easYgen-3500XT-P2 | LON not supported in easYgen! | | |
8406-114 | EGCP-3 "MC" | 8440-2222 | LS-6XT | LON not supported in LS-6XT | | |
8406-118 | EGCP-3 "LS 'l ENHANCED | 8440-2088 | easYgen-3500XT-P2 | LON not supported in easYgen! | | |
8406-119 | EGCP-3 tl MC" ENHANCED | 8440-2222 | LS-6XT | LON not supported in LS-6XT | | |
8406-124 | EGCP-3 "LSI ' (Customized) | 8440-2088 | easYgen-3500XT-P2 | LON not supported in easYgen! | | |
8406-125 | EGCP-3 "MC" (Customized) | 8440-2222 | LS-6XT | LON not supported in LS-6XT | | |
8440-1002 | MFR2S11B/A4HJM1SUVY08 | 8440-2088 | easYgen-3500XT-P2 | was RS232 DK3964 interface! | | |
8440-1005 | MFR1515B/CGU | 8440-2165 | SPM-D2-1115B/LSXR | Powerfactor control only | | |
8440-1006 | LS445B | 8440-2150 | LS-521-5 | Different CAN bus telegramm! LS5 not compatible with GCP-31, ESEPRO connected to LS5 emulate LS4 ProfibusDP Protcol | | |
8440-1011 | GCP-2245B/LSX | 8440-2082 | easYgen-3200XT | | | |
8440-1012 | GCP-2245B/LSB | 8440-2082 | easYgen-3200XT | | | |
8440-1013 | GCP-2145B/LSX | 8440-2082 | easYgen-3200XT | | | |
8440-1014 | GCP-2145B/LSB | 8440-2082 | easYgen-3200XT | | | |
8440-1016 | MFR1515B/SYN-I | 8440-2088 | easYgen-3500XT-P2 | different load shareline! Load share Gateway LSG | | |
8440-1019 | SPM-D1040B | 8440-2164 | SPM-D2-1040B | | | |
8440-1021 | SPM-D1040B/YB | 8440-2176 | SPM-D2-1040B/YB | | | |
8440-1022 | SPM-D2111B/PSV | 8440-2317 | LS-6XT-P2 | LS-6XT-P2 configured for active synchronization, consider 8446-1071 easYview HMI Display | | |
8440-1023 | SPM-D2115B/PSV | 8440-2317 | LS-6XT-P2 | LS-6XT-P2 configured for active synchronization, consider 8446-1071 easYview HMI Display | | |
8440-1024 | SPM-D2141B/PSV | 8440-2317 | LS-6XT-P2 | LS-6XT-P2 configured for active synchronization, consider 8446-1071 easYview HMI Display | | |
8440-1025 | SPM-D2145B/PSV | 8440-2317 | LS-6XT-P2 | LS-6XT-P2 configured for active synchronization, consider 8446-1071 easYview HMI Display | | |
8440-1026 | SPM-D2111B/PSVX | 8440-2317 | LS-6XT-P2 | LS-6XT-P2 configured for active synchronization, consider 8446-1071 easYview HMI Display | | |
8440-1027 | SPM-D2115B/PSVX | 8440-2317 | LS-6XT-P2 | LS-6XT-P2 configured for active synchronization, consider 8446-1071 easYview HMI Display | | |
8440-1029 | SPM-D2145B/PSVX | 8440-2317 | LS-6XT-P2 | LS-6XT-P2 configured for active synchronization, consider 8446-1071 easYview HMI Display | | |
8440-1030 | LS441B | 8440-2178 | LS-521-1 | Different CAN bus telegramm! LS5 not compatible with GCP-31, ESEPRO connected to LS5 emulate LS4 ProfibusDP Protcol | | |
8440-1031 | LS415B | 8440-2150 | LS-521-5 | Different CAN bus telegramm! LS5 not compatible with GCP-31, ESEPRO connected to LS5 emulate LS4 ProfibusDP Protcol | | |
8440-1032 | LS411B | 8440-2178 | LS-521-1 | Different CAN bus telegramm! LS5 not compatible with GCP-31, ESEPRO connected to LS5 emulate LS4 ProfibusDP Protcol | | |
8440-1038 | GCP-2045B/T2 | 8440-2281 | easYgen-3200XT-P1-LITE | | | |
8440-1041 | IKD1M | 8440-2028 | IKD1M | | | |
8440-1044 | AMG3S41B/CD1HJNPQUR1 | 8440-2082 | easYgen-3200XT | | | |
8440-1047 | AMG3A45B/N1PB | 8440-2082 | easYgen-3200XT | | | |
8440-1073 | ASG410+B | 8440-2164 | SPM-D2-1040B | | | |
8440-1081 | AMG3S41B/NEB-QF | 8440-2281 | easYgen-3200XT-P1-LITE | | | |
8440-1082 | AMG3S41B/NEB | 8440-2281 | easYgen-3200XT-P1-LITE | | | |
8440-1088 | MFR1545B/CGU | 8440-2169 | SPM-D2-1145B/LSXR | Powerfactor control only | | |
8440-1098 | ASG411+B/FRU | 8440-2169 | SPM-D2-1145B/LSXR | | | |
8440-1099 | ASG410+B/VJH | 8440-2169 | SPM-D2-1145B/LSXR | | | |
8440-1102 | MFR2S45B/PSV+A2MMBQUSB | 8440-2088 | easYgen-3500XT-P2 | easYgen-3000XT plus ESEPRO required | | |
8440-1103 | GCP-2215B/LSB | 8440-2082 | easYgen-3200XT | | | |
8440-1105 | MFR2S45B/PSV+SB | 8440-2082 | easYgen-3200XT | easYgen-3000XT plus ESEPRO required | | |
8440-1107 | AMG3S45B/N2PB-QFQU | 8440-2082 | easYgen-3200XT | | | |
8440-1115 | PCM1-M-45B/L | 8440-2088 | easYgen-3500XT-P2 | | | |
8440-1116 | PCM1-M-I1-U1-L | 8440-2088 | easYgen-3500XT-P2 | | | |
8440-1118 | PCM1-G-45B/L | 8440-2088 | easYgen-3500XT-P2 | | | |
8440-1123 | MPU2-S-45B/L | 8440-2088 | easYgen-3500XT-P2 | CAN protocols are not same! | | |
8440-1124 | MPU2-S-11B/M | 8440-2088 | easYgen-3500XT-P2 | CAN protocols are not same! | | |
8440-1127 | MPU2-S-11B/H | 8440-2088 | easYgen-3500XT-P2 | CAN protocols are not same! | | |
8440-1128 | MPU2-S-45B/H | 8440-2088 | easYgen-3500XT-P2 | CAN protocols are not same! | | |
8440-1131 | PCM1-M-11B/H-QFQU | 8440-2088 | easYgen-3500XT-P2 | | | |
8440-1154 | PCL1-I1-U1-H | 8440-2088 | easYgen-3500XT-P2 | | | |
8440-1156 | PCL1-I1-U1-L | 8440-2088 | easYgen-3500XT-P2 | | | |
8440-1157 | CONTROL-PCL1-45B/L | 8440-2088 | easYgen-3500XT-P2 | | | |
8440-1158 | PCL1-I1-U1-L-A | 8440-2088 | easYgen-3500XT-P2 | | | |
8440-1159 | PCL1-I5-U1-L-A | 8440-2088 | easYgen-3500XT-P2 | | | |
8440-1160 | PCL1-I1-U4-L-A | 8440-2088 | easYgen-3500XT-P2 | | | |
8440-1162 | PCL1-I1-U1-L-A | 8440-2088 | easYgen-3500XT-P2 | | | |
8440-1166 | PCL1-I5-U4-H-A | 8440-2088 | easYgen-3500XT-P2 | | | |
8440-1167 | PCL1-I1-U1-H-A | 8440-2088 | easYgen-3500XT-P2 | | | |
8440-1172 | MPU2-S-11B/L | 8440-2088 | easYgen-3500XT-P2 | CAN protocols are not same! | | |
8440-1173 | MPU2-S-15B/L | 8440-2088 | easYgen-3500XT-P2 | CAN protocols are not same! | | |
8440-1174 | MPU2-S-41B/L | 8440-2088 | easYgen-3500XT-P2 | CAN protocols are not same! | | |
8440-1180 | ASG410+10M/YB | 8440-2167 | SPM-D2-1010B/YB | DIN Rail Brackets 8923-1023 required | | |
8440-1184 | PCM1-M-15B/L | 8440-2088 | easYgen-3500XT-P2 | | | |
8440-1186 | CONTROL-PCL1-15B/L | 8440-2088 | easYgen-3500XT-P2 | | | |
8440-1187 | PCL1-I1-U4-L | 8440-2088 | easYgen-3500XT-P2 | | | |
8440-1196 | MFR1440B/SUUVY | 8440-2082 | easYgen-3200XT | | | |
8440-1229 | PCM1-M-I1-U4-L | 8440-2088 | easYgen-3500XT-P2 | | | |
8440-1242 | CONTROL-PCL1-45B/H | 8440-2088 | easYgen-3500XT-P2 | | | |
8440-1243 | CONTROL-PCL1-15B/H | 8440-2088 | easYgen-3500XT-P2 | | | |
8440-1244 | CONTROL-PCL1-41B/H | 8440-2088 | easYgen-3500XT-P2 | | | |
8440-1245 | PCL1-I1-U1-L-A | 8440-2088 | easYgen-3500XT-P2 | | | |
8440-1246 | PCL1-I1-U4-L-A | 8440-2088 | easYgen-3500XT-P2 | | | |
8440-1247 | PCL1-I1-U1-H-A | 8440-2088 | easYgen-3500XT-P2 | | | |
8440-1248 | PCL1-I1-U4-H-A | 8440-2088 | easYgen-3500XT-P2 | | | |
8440-1249 | PCL1-I1-U4-H-A | 8440-2088 | easYgen-3500XT-P2 | | | |
8440-1257 | MFR1545B/SYN | 8440-2082 | easYgen-3200XT | different load shareline! Load share Gateway LSG | | |
8440-1259 | ASG411+B/FU | 8440-2164 | SPM-D2-1040B | | | |
8440-1262 | AMG3S45B/N1PB-SFW | 8440-2082 | easYgen-3200XT | | | |
8440-1273 | AMG2S45B/N1PB-FGW01IN20QSFT4YM | 8440-2290 | easYgen-3500XT-P2-RENTAL | | | |
8440-1276 | SYNCON PANEL | | | Please consider an upgrade to an easYgen3000XT rental package with an LS-6XT and a self-made case. | | |
8440-1279 | AMG3S41B/NEB | 8440-2281 | easYgen-3200XT-P1-LITE | | | |
8440-1283 | AMG3S45B/NEB | 8440-2281 | easYgen-3200XT-P1-LITE | | | |
8440-1284 | AMG3S45B/N2PB-OQUSBS | 8440-2082 | easYgen-3200XT | | | |
8440-1286 | MFR2S15B/PSV | 8440-2082 | easYgen-3200XT | CAN protocols are not same! | | |
8440-1287 | MFR2S15B/PSVA | 8440-2088 | easYgen-3500XT-P2 | CAN protocols are not same! | | |
8440-1290 | ASG420+B | 8440-2317 | LS-6XT-P2 | LS-6XT-P2 configured for active synchronization, consider 8446-1071 easYview HMI Display | | |
8440-1293 | AMG3S45B/N1PB-SFT4X | 8440-2082 | easYgen-3200XT | replacement has only 3AIs | | |
8440-1295 | GCP-2115B/A2IN20OQFQ | 8440-2082 | easYgen-3200XT | | | |
8440-1301 | SPM-D1040B/X | 8440-2171 | SPM-D2-1040B/X | | | |
8440-1303 | MFR2A45B/PSV+SB | 8440-2082 | easYgen-3200XT | easYgen-3000XT plus ESEPRO required | | |
8440-1306 | PSY4-F-D | 8440-2170 | SPM-D2-10B/PSY5-FU-D | | | |
8440-1314 | ASG410+B/Y09 | 8440-2164 | SPM-D2-1040B | be careful - Synchronization over transformer | | |
8440-1316 | MFR2S15B/K02 | 8440-2082 | easYgen-3200XT | Modbus protocol is not same! | | |
8440-1323 | MFR2S45B/PSVA | 8440-2088 | easYgen-3500XT-P2 | CAN protocols are not same! | | |
8440-1326 | ASG410+10B/NYB | 8440-2177 | SPM-D2-1010B/NYB | | | |
8440-1329 | ASG411+B/QFQUR | 8440-2169 | SPM-D2-1145B/LSXR | | | |
8440-1335 | MFR2S45B/PSV+A2I3SB | 8440-2088 | easYgen-3500XT-P2 | Modbus protocol is not same! | | |
8440-1336 | AMG2S45B/N2PB-A2SC02SFT7 | 8440-2088 | easYgen-3500XT-P2 | | | |
8440-1346 | GCP-2115B/LSR | 8440-2082 | easYgen-3200XT | | | |
8440-1348 | MFR2S41B/PSV+I3 | 8440-2082 | easYgen-3200XT | CANbus protocol is not same! | | |
8440-1351 | GCP-3115B/A2IN20QSBSFT7XZEZS | 8440-2088 | easYgen-3500XT-P2 | | | |
8440-1358 | ASG410+10B/YB | 8440-2167 | SPM-D2-1010B/YB | | | |
8440-1360 | MFR2S15B/PSV+SU | 8440-2082 | easYgen-3200XT | easYgen-3000XT plus ESEPRO required | | |
8440-1361 | ASG411+B/A22FRU | 8440-2281 | easYgen-3200XT-P1-LITE | | | |
8440-1362 | MFR2S45B/PSV-A2MMBQUXXC | 8440-2088 | easYgen-3500XT-P2 | CAN protocols are not same! | | |
8440-1365 | MFR31S45B/PSV+Q | 8440-2088 | easYgen-3500XT-P2 | CAN protocols are not same! | | |
8440-1367 | GCP-2245B/LSX | 8440-2082 | easYgen-3200XT | | | |
8440-1369 | GCP-2245B/LSX | 8440-2082 | easYgen-3200XT | | | |
8440-1376 | AMG2S45B/N1PB-D04IM01PM03QFSBT7TZ02ZEZS | 8440-2088 | easYgen-3500XT-P2 | | | |
8440-1383 | ASG410+10B/NYB | 8440-2177 | SPM-D2-1010B/NYB | | | |
8440-1384 | AMG3S45B/NEB-QF | 8440-2281 | easYgen-3200XT-P1-LITE | | | |
8440-1385 | ASG411+B/A22CPQURUFVJH | 8440-2281 | easYgen-3200XT-P1-LITE | | | |
8440-1399 | MFR2S11B/PSV-A2SB | 8440-2082 | easYgen-3200XT | Modbus protocol is not same! | | |
8440-1405 | MFR2S45B/PSV+D06QFQUSB | 8440-2082 | easYgen-3200XT | easYgen-3000XT plus ESEPRO required | | |
8440-1407 | MFR2S45B/PSV+A2K06MMBQUSFXXC | 8440-2088 | easYgen-3500XT-P2 | | | |
8440-1409 | MFR2S45B/A2CD06D09HI1I4JK24MMB | 8440-2088 | easYgen-3500XT-P2 | | | |
8440-1410 | MFR2S45B/PSV+A2DMMBQUSBSFX | 8440-2088 | easYgen-3500XT-P2 | Modbus protocol is not same! | | |
8440-1418 | PSY4-FU-D | 8440-2170 | SPM-D2-10B/PSY5-FU-D | | | |
8440-1419 | PSY5-FU-D | 8440-2173 | SPM-D2-10B/PSY5-FU-D-W | | | |
8440-1420 | PSY5-FU-A | 8440-2171 | SPM-D2-10X | | | |
8440-1421 | PSY5-FU-D-W | 8440-2173 | SPM-D2-10B/PSY5-FU-D-W | | | |
8440-1422 | PSY5-FU-A-W | 8440-2173 | SPM-D2-10B/PSY5-FU-D-W | up &down relays for U and f +/-, alternative SPM-D210-NX | | |
8440-1428 | MFR2S45B/PSV+A2I3SB | 8440-2088 | easYgen-3500XT-P2 | easYgen-3000XT plus ESEPRO required | | |
8440-1430 | MFR31S45B/PSV-ZS | 8440-2088 | easYgen-3500XT-P2 | CAN protocols are not same! | | |
8440-1431 | MFR2S15B/PSV+MMBQFSB | 8440-2088 | easYgen-3500XT-P2 | easYgen-3000XT plus ESEPRO required | | |
8440-1432 | SPM-D1010B/N | 8440-2174 | SPM-D2-1010B/N | | | |
8440-1433 | SPM-D1040B/N | 8440-2175 | SPM-D2-1040B/N | | | |
8440-1434 | SPM-D1010B/NYB | 8440-2177 | SPM-D2-1010B/NYB | | | |
8440-1435 | SPM-D1040B/NYB | 8440-2189 | SPM-D2-1040B/NYB | | | |
8440-1436 | MFR2S15B/PSVT+DI3SB | 8440-2082 | easYgen-3200XT | easYgen-3000XT plus ESEPRO required | | |
8440-1442 | MFR2S15B/PSVT+A2K06MMBQUSFXXC | 8440-2082 | easYgen-3200XT | CAN protocols are not same! | | |
8440-1444 | AMG3S45B/N2PB-QFQUX | 8440-2082 | easYgen-3200XT | | | |
8440-1445 | MFR2S45B/PSV+A2DK06MMBQUSFXXC | 8440-2082 | easYgen-3200XT | CAN protocols are not same! | | |
8440-1446 | AMG3S45B/NEB-QF | 8440-2281 | easYgen-3200XT-P1-LITE | | | |
8440-1448 | MFR1545B/SYN-I | 8440-2088 | easYgen-3500XT-P2 | different load shareline! Load share Gateway LSG | | |
8440-1449 | MFR2S41B/PSV+A2D06MMBQUSB | 8440-2082 | easYgen-3200XT | easYgen-3000XT plus ESEPRO required | | |
8440-1452 | MFR2A45B/PSV | 8440-2281 | easYgen-3200XT-P1-LITE | EPU-100 required | | |
8440-1457 | GCP-2045B | 8440-2281 | easYgen-3200XT-P1-LITE | | | |
8440-1458 | SPM-D1040B/HJV | 8440-2082 | easYgen-3200XT | | | |
8440-1459 | GCP-3145B/A2L4QSBCCM01SFT701ZE | 8440-2088 | easYgen-3500XT-P2 | | | |
8440-1461 | AMG2S11B/N1PB-A2SC02SFT7 | 8440-2088 | easYgen-3500XT-P2 | | | |
8440-1465 | MFR2S45B/PSV+A2MMBSB-EWA004 | 8440-2082 | easYgen-3200XT | RS232 DK3964 Interface! | | |
8440-1466 | PCL1-11B/L-A | 8440-2088 | easYgen-3500XT-P2 | | | |
8440-1467 | PCL1-15B/L-A | 8440-2088 | easYgen-3500XT-P2 | | | |
8440-1468 | PCL1-41B/L-A | 8440-2088 | easYgen-3500XT-P2 | | | |
8440-1469 | PCL1-45B/L-A | 8440-2088 | easYgen-3500XT-P2 | | | |
8440-1473 | PCL1-45B/H-A | 8440-2088 | easYgen-3500XT-P2 | | | |
8440-1474 | PCM1-G-I1-U1-L-I | 8440-2088 | easYgen-3500XT-P2 | | | |
8440-1475 | PCM1-G-I5-U1-L-I | 8440-2088 | easYgen-3500XT-P2 | | | |
8440-1476 | PCM1-G-41B/L-I | 8440-2088 | easYgen-3500XT-P2 | | | |
8440-1477 | PCM1-G-45B/L-I | 8440-2088 | easYgen-3500XT-P2 | | | |
8440-1478 | PCM1-G-11B/L-I-A | 8440-2088 | easYgen-3500XT-P2 | | | |
8440-1479 | PCM1-G-15B/L-I-A | 8440-2088 | easYgen-3500XT-P2 | | | |
8440-1480 | PCM1-G-41B/L-I-A | 8440-2088 | easYgen-3500XT-P2 | | | |
8440-1481 | PCM1-G-45B/L-I-A | 8440-2088 | easYgen-3500XT-P2 | | | |
8440-1482 | PCM1-G-I1-U1-H-I | 8440-2088 | easYgen-3500XT-P2 | | | |
8440-1483 | PCM1-G-15B/H-I | 8440-2088 | easYgen-3500XT-P2 | | | |
8440-1484 | PCM1-G-41B/H-I | 8440-2088 | easYgen-3500XT-P2 | | | |
8440-1485 | PCM1-G-45B/H-I | 8440-2088 | easYgen-3500XT-P2 | | | |
8440-1485 | PCM1-G-I5-U4-H-I | 8440-2088 | easYgen-3500XT-P2 | | | |
8440-1486 | PCM1-G-11B/H-I-A | 8440-2088 | easYgen-3500XT-P2 | | | |
8440-1487 | PCM1-G-15B/H-I-A | 8440-2088 | easYgen-3500XT-P2 | | | |
8440-1488 | PCM1-G-41B/H-I-A | 8440-2088 | easYgen-3500XT-P2 | | | |
8440-1489 | PCM1-G-45B/H-I-A | 8440-2088 | easYgen-3500XT-P2 | | | |
8440-1490 | PCM1-G-11B/H-E | 8440-2088 | easYgen-3500XT-P2 | | | |
8440-1491 | PCM1-G-15B/H-E | 8440-2088 | easYgen-3500XT-P2 | | | |
8440-1492 | PCM1-G-41B/H-E | 8440-2088 | easYgen-3500XT-P2 | | | |
8440-1493 | PCM1-G-45B/H-E | 8440-2088 | easYgen-3500XT-P2 | | | |
8440-1494 | PCM1-G-11B/H-E-A | 8440-2088 | easYgen-3500XT-P2 | | | |
8440-1495 | PCM1-G-15B/H-E-A | 8440-2088 | easYgen-3500XT-P2 | | | |
8440-1496 | PCM1-G-41B/H-E-A | 8440-2088 | easYgen-3500XT-P2 | | | |
8440-1497 | PCM1-G-I5-U4-H-E-A | 8440-2088 | easYgen-3500XT-P2 | | | |
8440-1498 | PCM1-M-11B/L-A | 8440-2088 | easYgen-3500XT-P2 | | | |
8440-1499 | PCM1-M-15B/L-A | 8440-2088 | easYgen-3500XT-P2 | | | |
8440-1500 | PCM1-M-41B/L-A | 8440-2088 | easYgen-3500XT-P2 | | | |
8440-1501 | PCM1-M-45B/L-A | 8440-2088 | easYgen-3500XT-P2 | | | |
8440-1502 | PCM1-M-I1-U1-H | 8440-2088 | easYgen-3500XT-P2 | | | |
8440-1503 | PCM1-M-15B/H | 8440-2088 | easYgen-3500XT-P2 | | | |
8440-1504 | PCM1-M-41B/H | 8440-2088 | easYgen-3500XT-P2 | | | |
8440-1505 | PCM1-M-I5-U4-H | 8440-2088 | easYgen-3500XT-P2 | | | |
8440-1506 | PCM1-M-11B/H-A | 8440-2088 | easYgen-3500XT-P2 | | | |
8440-1507 | PCM1-M-15B/H-A | 8440-2088 | easYgen-3500XT-P2 | | | |
8440-1508 | PCM1-M-I1-U4-H-A | 8440-2088 | easYgen-3500XT-P2 | | | |
8440-1509 | PCM1-M-I5-U4-H-A | 8440-2088 | easYgen-3500XT-P2 | | | |
8440-1510 | LS415B/K12 | 8440-2221 | CONTROL-LS-521-5/P1-K12 | | | |
8440-1514 | GCP-3145B/A2K10QSFT701ZE | 8440-2088 | easYgen-3500XT-P2 | | | |
8440-1516 | AMG2S45B/A2EEA1 | | | customized, there should be stock based on a last time buy available | | |
8440-1522 | GCP-21A15B/A2QFSBT4X | 8440-2281 | easYgen-3200XT-P1-LITE | EPU-100 required | | |
8440-1528 | MFR2S15B/PSV+A2I3SB | 8440-2088 | easYgen-3500XT-P2 | easYgen-3000XT plus ESEPRO required | | |
8440-1538 | AMG2S41B/N2PB+A2SC10SFT702 | 8440-2088 | easYgen-3500XT-P2 | | | |
8440-1540 | MFR32S15B/PSV-IN20QSBZS | 8440-2088 | easYgen-3500XT-P2 | Modbus protocol is not same! | | |
8440-1541 | GCP-2115B/LSB | 8440-2082 | easYgen-3200XT | | | |
8440-1542 | MFR2S41B/PSV+A2I3SB | 8440-2088 | easYgen-3500XT-P2 | different Modbus protocol | | |
8440-1546 | MFR2S45B/A2CDD06D09HI1I4JK24MM | 8440-2088 | easYgen-3500XT-P2 | | | |
8440-1551 | GCP-3145B/BPD | 8440-2082 | easYgen-3200XT | | | |
8440-1552 | GCP-3111B/XPD | 8440-2082 | easYgen-3200XT | | | |
8440-1553 | GCP-3141B/XPD | 8440-2082 | easYgen-3200XT | | | |
8440-1555 | GCP-3145B/XPD | 8440-2082 | easYgen-3200XT | | | |
8440-1556 | GCP-3111B/XPQ | 8440-2088 | easYgen-3500XT-P2 | | | |
8440-1557 | GCP-3141B/XPQ | 8440-2082 | easYgen-3200XT | | | |
8440-1558 | GCP-3115B/XPQ | 8440-2088 | easYgen-3500XT-P2 | | | |
8440-1559 | GCP-3145B/XPQ | 8440-2088 | easYgen-3500XT-P2 | | | |
8440-1560 | GCP-3115B/XPQ+SC10 | 8440-2088 | easYgen-3500XT-P2 | | | |
8440-1561 | GCP-3145B/XPQ+SC10 | 8440-2088 | easYgen-3500XT-P2 | | | |
8440-1562 | GCP-3115B/XPQ+SB03 | 8440-2088 | easYgen-3500XT-P2 | CAT CCM not supported in replacement | | |
8440-1563 | GCP-3145B/XPQ+SB03 | 8440-2088 | easYgen-3500XT-P2 | | | |
8440-1566 | GCP-3215B/BPD | 8440-2082 | easYgen-3200XT | | | |
8440-1567 | GCP-3245B/BPD | 8440-2082 | easYgen-3200XT | | | |
8440-1568 | GCP-3211B/XPD | 8440-2082 | easYgen-3200XT | | | |
8440-1571 | GCP-3245B/XPD | 8440-2082 | easYgen-3200XT | | | |
8440-1572 | GCP-3211B/XPQ | 8440-2088 | easYgen-3500XT-P2 | | | |
8440-1573 | GCP-3241B/XPQ | 8440-2088 | easYgen-3500XT-P2 | | | |
8440-1574 | GCP-3215B/XPQ | 8440-2088 | easYgen-3500XT-P2 | | | |
8440-1575 | GCP-3245B/XPQ | 8440-2088 | easYgen-3500XT-P2 | | | |
8440-1576 | GCP-3215B/XPQ+SC10 | 8440-2088 | easYgen-3500XT-P2 | | | |
8440-1577 | GCP-3245B/XPQ+SC10 | 8440-2088 | easYgen-3500XT-P2 | | | |
8440-1578 | GCP-3215B/XPQ+SB03 | 8440-2088 | easYgen-3500XT-P2 | CAT CCM not supported in replacement | | |
8440-1579 | GCP-3245B/XPQ+SB03 | 8440-2088 | easYgen-3500XT-P2 | CAT CCM not supported in replacement | | |
8440-1581 | GCP-2015B/LS | 8440-2082 | easYgen-3200XT | | | |
8440-1586 | GCP-2115B/LS | 8440-2082 | easYgen-3200XT | | | |
8440-1587 | GCP-2115B/LSX | 8440-2082 | easYgen-3200XT | | | |
8440-1590 | GCP-2215B/LS | 8440-2082 | easYgen-3200XT | | | |
8440-1592 | MFR1545B/SY | 8440-2082 | easYgen-3200XT | different load shareline! Load share Gateway LSG | | |
8440-1600 | SPM-D1010B/HJV | 8440-2082 | easYgen-3200XT | | | |
8440-1609 | GCP-3115B/BPQ | 8440-2082 | easYgen-3200XT | | | |
8440-1610 | GCP-3145B/BPQ | 8440-2082 | easYgen-3200XT | | | |
8440-1612 | GCP-3241B/BPQ | 8440-2082 | easYgen-3200XT | | | |
8440-1613 | GCP-3215B/BPQ | 8440-2082 | easYgen-3200XT | | | |
8440-1614 | GCP-3245B/BPQ | 8440-2082 | easYgen-3200XT | | | |
8440-1617 | MFR2S41B/PSV+A2I3SB | 8440-2088 | easYgen-3500XT-P2 | easYgen-3000XT plus ESEPRO required | | |
8440-1624 | AMG3S45B/N2PB-QFX | 8440-2082 | easYgen-3200XT | | | |
8440-1628 | MFR31S11B/PSV+ZS | 8440-2088 | easYgen-3500XT-P2 | CAN protocols are not same! | | |
8440-1631 | MFR31S15B/PSVX+Q | 8440-2088 | easYgen-3500XT-P2 | | | |
8440-1632 | MFR31S45B/PSVX+Q | 8440-2088 | easYgen-3500XT-P2 | | | |
8440-1633 | MFR32S15B/PSVX+Q | 8440-2088 | easYgen-3500XT-P2 | | | |
8440-1634 | MFR32S45B/PSVX+Q | 8440-2088 | easYgen-3500XT-P2 | | | |
8440-1650 | MFR31S11B/PSV+K14ZS | 8440-2088 | easYgen-3500XT-P2 | | | |
8440-1651 | MFR31S45B/PSV+K14ZS | 8440-2088 | easYgen-3500XT-P2 | | | |
8440-1652 | MFR2S11B/PSV+A2K06MMBQUSFXXC | 8440-2088 | easYgen-3500XT-P2 | CAN protocols are not same! | | |
8440-1653 | AMG3S45B/N1PB-SFT4WX | 8440-2082 | easYgen-3200XT | replacement has only 3AIs | | |
8440-1658 | GCP-3145B/XPD+SC10 | 8440-2088 | easYgen-3500XT-P2 | | | |
8440-1662 | PCM1-M-I5-U4-P01 | 8440-2088 | easYgen-3500XT-P2 | | | |
8440-1663 | MFR2S11B/PSV+SB | 8440-2082 | easYgen-3200XT | easYgen-3000XT plus ESEPRO required | | |
8440-1664 | GCP-3241B/XPQ+SC10 | 8440-2088 | easYgen-3500XT-P2 | | | |
8440-1665 | MFR2S11B/PSV+A2I3SB | 8440-2088 | easYgen-3500XT-P2 | different Modbus protocol | | |
8440-1666 | SPM-D1145B/LSXR | 8440-2169 | SPM-D2-1145B/LSXR | | | |
8440-1667 | SPM-D1010B/XN | 8440-2172 | SPM-D2-1010B/XN | | | |
8440-1668 | SPM-D1040B/XN | 8440-2190 | SPM-D2-1040B/XN | | | |
8440-1675 | GCP-3245B/XPD+SC10 | 8440-2088 | easYgen-3500XT-P2 | | | |
8440-1678 | AMG2S45B/N1PB+D08QSC10SFT710ZS | 8440-2088 | easYgen-3500XT-P2 | | | |
8440-1681 | MFR2S11B/PSV+A2I3SB | 8440-2088 | easYgen-3500XT-P2 | easYgen-3000XT plus ESEPRO required | | |
8440-1682 | GCP-3211B/XPD+SC10 | 8440-2088 | easYgen-3500XT-P2 | | | |
8440-1683 | GCP-3241B/XPD+SC10 | 8440-2088 | easYgen-3500XT-P2 | | | |
8440-1685 | GCP-3145B/BPQ+SC10 | 8440-2088 | easYgen-3500XT-P2 | | | |
8440-1686 | SPM-D1145B/LSR | 8440-2169 | SPM-D2-1145B/LSXR | | | |
8440-1688 | GCP-3211B/XPQ+SC10 | 8440-2088 | easYgen-3500XT-P2 | | | |
8440-1694 | MFR2S11B/PSVT+A2I3SB | 8440-2088 | easYgen-3500XT-P2 | different Modbus protocol | | |
8440-1695 | MFR2S15B/PSV+A2I3SB | 8440-2088 | easYgen-3500XT-P2 | different protocol - ESEPRO required | | |
8440-1697 | AMG2S41B/N2PB+A2SC10SFT707ZS | 8440-2088 | easYgen-3500XT-P2 | | | |
8440-1703 | SPM-D1115B/LSR | 8440-2169 | SPM-D2-1145B/LSXR | | | |
8440-1705 | SPM-D1111B/LSXR | 8440-2165 | SPM-D2-1115B/LSXR | external CTs must changed to ../5A ! | | |
8440-1706 | SPM-D1115B/LSXR | 8440-2165 | SPM-D2-1115B/LSXR | | | |
8440-1708 | SPM-D1111B/LSR | 8440-2165 | SPM-D2-1115B/LSXR | external CTs must changed to ../5A ! | | |
8440-1709 | SPM-D1115B/LSR | 8440-2165 | SPM-D2-1115B/LSXR | | | |
8440-1711 | SPM-D1145B/LSR | 8440-2169 | SPM-D2-1145B/LSXR | | | |
8440-1713 | SPM-D1115B/LSXR | 8440-2165 | SPM-D2-1115B/LSXR | | | |
8440-1715 | SPM-D1145B/LSXR | 8440-2169 | SPM-D2-1145B/LSXR | | | |
8440-1716 | GCP-3141B/XPQ+SC10 | 8440-2088 | easYgen-3500XT-P2 | | | |
8440-1719 | GCP-3141B/SC06SFT711ZS | 8440-2088 | easYgen-3500XT-P2 | | | |
8440-1722 | MFR1541B/SYN | 8440-2082 | easYgen-3200XT | different load shareline! Load share Gateway LSG | | |
8440-1728 | GCP-2145B/OQFSFT4W | 8440-2082 | easYgen-3200XT | | | |
8440-1731 | MFR32S11B/PSV+Q | 8440-2088 | easYgen-3500XT-P2 | CAN protocols are not same! | | |
8440-1732 | MFR2S15B/PSV | 8440-2082 | easYgen-3200XT | CAN protocols are not same! | | |
8440-1733 | MFR2S15B/PSVA | 8440-2088 | easYgen-3500XT-P2 | | | |
8440-1735 | MFR2S45B/PSVA | 8440-2088 | easYgen-3500XT-P2 | | | |
8440-1743 | AMG3A45B/N1PB+SFT4X | 8440-2082 | easYgen-3200XT | replacement has only 3AIs | | |
8440-1744 | MFR2S11B/PSVT+A2I3SB | 8440-2088 | easYgen-3500XT-P2 | easYgen-3000XT plus ESEPRO required | | |
8440-1756 | MFR32S11B/PSVX | 8440-2088 | easYgen-3500XT-P2 | CAN protocols are not same! | | |
8440-1761 | MFR2S15B/PSV+A2QUSB | 8440-2088 | easYgen-3500XT-P2 | easYgen-3000XT plus ESEPRO required | | |
8440-1762 | AMG2S11B/N2PB+A2SC10SFT707ZS | 8440-2088 | easYgen-3500XT-P2 | | | |
8440-1764 | GCP-3145B/RPQ+SC09 | 8440-2088 | easYgen-3500XT-P2 | | | |
8440-1765 | MFR2S11B/PSV+A2I3SB | 8440-2088 | easYgen-3500XT-P2 | easYgen-3000XT plus ESEPRO required | | |
8440-1771 | MFR1515B/A3BCDIZMPMPSSUUVXYZQ | 8440-2082 | easYgen-3200XT | different load shareline! Load share Gateway LSG | | |
8440-1774 | NDC1-51B | 8440-1810 | easYgen-1500-1 | | | |
8440-1775 | NDC1-55B | 8440-1809 | easYgen-1500-5 | | | |
8440-1778 | DTSC-200-51B | 8440-1867 | DTSC-200-1 | LEOPC version replaced with Toolkit version | | |
8440-1779 | DTSC-200-55B | 8440-1868 | DTSC-200-5 | LEOPC version replaced with Toolkit version | | |
8440-1781 | NAC1-G-L | 8440-1800 | easYgen-320-50B/X | | | |
8440-1782 | NAC1-G-H | 8440-1800 | easYgen-320-50B/X | | | |
8440-1783 | NAC1-G-L | 8440-1801 | easYgen-350-50B/X | | | |
8440-1784 | NAC1-G-H | 8440-1801 | easYgen-350-50B/X | | | |
8440-1786 | easYgen-350-50B/X | 8440-1801 | easYgen-350X | | | |
8440-1787 | MFR2S45B/PSVA+SB | 8440-2088 | easYgen-3500XT-P2 | easYgen-3000XT plus ESEPRO required | | |
8440-1798 | easYgen-320-50B | 8440-1800 | easYgen-320X | | | |
8440-1799 | easYgen-350-50B | 8440-1801 | easYgen-350X | | | |
8440-1802 | MFR2S45B/PSV+D06QFQUSB | 8440-2088 | easYgen-3500XT-P2 | easYgen-3000XT plus ESEPRO required | | |
8440-1806 | GCP-3111B/XPQ+SC10 | 8440-2088 | easYgen-3500XT-P2 | | | |
8440-1814 | easYgen-1500-55B | 8440-1809 | easYgen-1500-5 | | | |
8440-1815 | MFR2S11B/A2CD06D09HI1I4JK24MMB | 8440-2088 | easYgen-3500XT-P2 | | | |
8440-1816 | easYgen-3200-1 | 8440-2049 | easYgen-3200-1 | | | |
8440-1817 | easYgen-3100-5 | 8440-2054 | easYgen-3100-5 | | | |
8440-1818 | easYgen-3100-1 | 8440-2055 | easYgen-3100-1 | | | |
8440-1822 | easYgen-1500-55B/K22 | 8440-1809 | easYgen-1500-5 | | | |
8440-1823 | NDC1-51B | 8440-1810 | easYgen-1500-1 | | | |
8440-1824 | NDC1-55B | 8440-1809 | easYgen-1500-5 | | | |
8440-1829 | MFR2S45B/PSV+A2I3SB | 8440-2088 | easYgen-3500XT-P2 | different Modbus protocol | | |
8440-1830 | GCP-2115B/OQFSFT4W | 8440-2082 | easYgen-3200XT | | | |
8440-1831 | easYgen-3200-5 | 8440-2050 | easYgen-3200-5 | | | |
8440-1832 | GCP-3145B/XPQ+D10D11SC10 | 8440-2088 | easYgen-3500XT-P2 | | | |
8440-1836 | MFR2S45B/PSV+A2I3SB | 8440-2088 | easYgen-3500XT-P2 | easYgen-3000XT plus ESEPRO required | | |
8440-1838 | MFR2S11B/PSVA | 8440-2088 | easYgen-3500XT-P2 | CAN protocols are not same! | | |
8440-1839 | MFR2S11B/PSVA | 8440-2088 | easYgen-3500XT-P2 | CAN protocols are not same! | | |
8440-1842 | easYgen-3200-1/P2 | 8440-2051 | easYgen-3200-1/P2 | | | |
8440-1843 | easYgen-3200-5/P2 | 8440-2052 | easYgen-3200-5/P2 | | | |
8440-1844 | easYgen-3100-1/P2 | 8440-2057 | easYgen-3100-1/P2 | | | |
8440-1845 | easYgen-3100-5/P2 | 8440-2056 | easYgen-3100-5/P2 | | | |
8440-1846 | MFR31S15B/PSV+K14ZS | 8440-2088 | easYgen-3500XT-P2 | | | |
8440-1848 | easYgen-3200-5 | 8440-2050 | easYgen-3200-5 | | | |
8440-1849 | MFR1515B/BCIZMPMPSSBSB01UUSU07 | 8440-2088 | easYgen-3500XT-P2 | different load shareline! Load share Gateway LSG | | |
8440-1852 | MFR2S11B/A2CDD06D09HI1I4JK24MM | 8440-2088 | easYgen-3500XT-P2 | | | |
8440-1854 | AMG2S45B/N2PB+A2K01M03QSFT717Z | 8440-2088 | easYgen-3500XT-P2 | Customized | | |
8440-1871 | SPM-D10B/PSY5-FU-D | 8440-2170 | SPM-D2-10B/PSY5-FU-D | | | |
8440-1872 | SPM-D10B/PSY5-FU-A | 8440-2170 | SPM-D2-10B/PSY5-FU-D | use additional external electronic DI/AO Motorpoti | | |
8440-1873 | SPM-D10B/PSY5-FU-D-W | 8440-2173 | SPM-D2-10B/PSY5-FU-D-W | | | |
8440-1874 | SPM-D10B/PSY5-FU-A-W | 8440-2173 | SPM-D2-10B/PSY5-FU-D-W | use additional external electronic DI/AO Motorpoti | | |
8440-1876 | easYgen-3200-5/K25 | 8440-2050 | easYgen-3200-5 | | | |
8440-1896 | GCP-2245B/LS | 8440-2082 | easYgen-3200XT | | | |
8440-1902 | easYgen-3200-5/K25 | 8440-2050 | easYgen-3200-5 | | | |
8440-1908 | easYgen-3200-5 | 8440-2050 | easYgen-3200-5 | | | |
8440-1910 | easYgen-3200-5/K27 | 8440-2085 | easYgen-3500XT-P1 | run up synchronization | | |
8440-1911 | easYgen-3200-5/P2 | 8440-2052 | easYgen-3200-5/P2 | | | |
8440-1915 | easYgen-3200-1/K25 | 8440-2049 | easYgen-3200-1 | | | |
8440-1920 | easYgen-1500-55B/LP01 | 8440-1809 | easYgen-1500-5 | | | |
8440-1921 | easYgen-2500-5/P1 | 8440-1884 | easYgen-2500-5 | | | |
8440-1922 | easYgen-3200-1/P1 | 8440-2049 | easYgen-3200-1/P1 | | | |
8440-1923 | easYgen-3200-5/P1 | 8440-2050 | easYgen-3200-5/P1 | | | |
8440-1924 | easYgen-3200-1/P2 | 8440-2051 | easYgen-3200-1/P2 | | | |
8440-1925 | easYgen-3200-5/P2 | 8440-2052 | easYgen-3200-5/P2 | | | |
8440-1927 | easYgen-3200-5/P1 | 8440-2050 | easYgen-3200-5/P1 | | | |
8440-1930 | easYgen-3100-5/P1 | 8440-2054 | easYgen-3100-5/P1 | | | |
8440-1931 | easYgen-3100-1/P1 | 8440-2055 | easYgen-3100-1/P1 | | | |
8440-1932 | easYgen-3100-5/P2 | 8440-2056 | easYgen-3100-5/P2 | | | |
8440-1932 | easYgen-3100-5/P2 | 8440-2056 | easYgen-3100-5-P2 | 8440-2081 easYgen-3100XT + RP3000XT | | |
8440-1933 | easYgen-3100-1/P2 | 8440-2057 | easYgen-3100-1/P2 | | | |
8440-1943 | easYgen-3200-5/P2 | 8440-2052 | easYgen-3200-5/P2 | | | |
8440-1946 | LS-511-5/P1 | 8440-2152 | LS-511-5/P1 | current sensing with 6 terminals | | |
8440-1947 | LS-521-5/P1 | 8440-2150 | LS-521-5/P1 | current sensing with 6 terminals | | |
8440-1951 | LS-511-1/P1 | 8440-2180 | LS-511-1/P1 | current sensing with 6 terminals | | |
8440-1952 | LS-521-1/P1 | 8440-2178 | LS-521-1/P1 | current sensing with 6 terminals | | |
8440-1960 | easYgen-3200-5/P1 | 8440-2050 | easYgen-3200-5/P1 | | | |
8440-1963 | easYgen-3100-5/P1 | 8440-2054 | easYgen-3100-5/P1 | | | |
8440-1963 | easYgen-3100-5/P1 | 8440-2054 | easYgen-3100-5-P1 | 8440-2081 easYgen-3100XT + RP3000XT | | |
8440-1964 | easYgen-3200-5/P2 | 8440-2052 | easYgen-3200-5/P2 | | | |
8440-1965 | easYgen-3200-5/K27 | 8440-1934 | easYgen-3500-5 | run up synchronization | | |
8440-1968 | easYgen-3200-1/P1 | 8440-2049 | easYgen-3200-1/P1 | | | |
8440-1969 | easYgen-3100-1/P1 | 8440-2055 | easYgen-3100-1/P1 | | | |
8440-1970 | easYgen-3200-1/P2 | 8440-2051 | easYgen-3200-1/P2 | | | |
8440-1971 | easYgen-3200-5/P2 | 8440-2052 | easYgen-3200-5/P2 | | | |
8440-1972 | easYgen-3100-1/P2 | 8440-2057 | easYgen-3100-1/P2 | | | |
8440-1973 | easYgen-3100-5/P2 | 8440-2056 | easYgen-3100-5/P2 | | | |
8440-1974 | easYgen-3100-1/P2 | 8440-2057 | easYgen-3100-1/P2 | | | |
8440-1974 | easYgen-3100-1/P2 | 8440-2057 | easYgen-3100-1-P2 | 8440-2081 easYgen-3100XT + RP3000XT | | |
8440-1992 | easYgen-3200-5/P1 | 8440-2050 | easYgen-3200-5/P1 | | | |
8440-1992 | easYgen-3200-5/P1 | 8440-2050 | easYgen-3200-5-P1 | 8440-2082 easYgen-3200XT | | |
8440-1993 | easYgen-3200-5/P1 | 8440-2050 | easYgen-3200-5/P1 | | | |
8440-1994 | easYgen-3200-5/P2 | 8440-2052 | easYgen-3200-5/P2 | | | |
8440-1995 | easYgen-3200-5/P2 | 8440-2052 | easYgen-3200-5/P2 | | | |
8440-1996 | easYgen-3200-5/P2 | 8440-2052 | easYgen-3200-5/P2 | | | |
8440-1997 | easYgen-3100-1/P2 | 8440-2057 | easYgen-3100-1/P2 | | | |
8440-1997 | easYgen-3100-1/P2 | 8440-2057 | easYgen-3100-1-P2 | 8440-2081 easYgen-3100XT + RP3000XT | | |
8440-1998 | easYgen-3200-1 | 8440-2049 | easYgen-3200-1 | | | |
8440-1999 | easYgen-3100-5 | 8440-2054 | easYgen-3100-5 | | | |
8440-2000 | easYgen-3100-1 | 8440-2055 | easYgen-3100-1 | | | |
8440-2001 | easYgen-3200-5 | 8440-2050 | easYgen-3200-5 | | | |
8440-2001 | easYgen-3200-5 | 8440-2050 | easYgen-3200-5-P1 | 8440-2082 easYgen-3200XT | | |
8440-2002 | easYgen-3200-1/P2 | 8440-2051 | easYgen-3200-1/P2 | | | |
8440-2003 | easYgen-3200-5/P2 | 8440-2052 | easYgen-3200-5/P2 | | | |
8440-2004 | easYgen-3100-1/P2 | 8440-2057 | easYgen-3100-1/P2 | | | |
8440-2005 | easYgen-3100-5/P2 | 8440-2056 | easYgen-3100-5/P2 | | | |
8440-2006 | easYgen-3200-5 | 8440-2050 | easYgen-3200-5 | | | |
8440-2007 | easYgen-3200-5/K25 | 8440-2050 | easYgen-3200-5 | | | |
8440-2008 | easYgen-3200-5/K25 | 8440-2050 | easYgen-3200-5 | | | |
8440-2009 | easYgen-3200-5 | 8440-2050 | easYgen-3200-5 | | | |
8440-2010 | easYgen-3200-5/K27 | 8440-1934 | easYgen-3500-5 | run up synchronization | | |
8440-2011 | easYgen-3200-5/P2 | 8440-2052 | easYgen-3200-5/P2 | | | |
8440-2012 | easYgen-3200-1/K25 | 8440-2049 | easYgen-3200-1 | | | |
8440-2013 | easYgen-3200-5/P2 | 8440-2052 | easYgen-3200-5/P2 | | | |
8440-2014 | easYgen-3200-5/P2 | 8440-2052 | easYgen-3200-5/P2 | | | |
8440-2015 | easYgen-3200-5/K27 | 8440-1934 | easYgen-3500-5 | run up synchronization | | |
8440-2016 | easYgen-3100-1/P2 | 8440-2057 | easYgen-3100-1/P2 | | | |
8440-2017 | easYgen-3200-5/P1 | 8440-2050 | easYgen-3200-5/P1 | | | |
8440-2018 | easYgen-3200-5/P1 | 8440-2050 | easYgen-3200-5/P1 | | | |
8440-2019 | easYgen-3200-5/P2 | 8440-2052 | easYgen-3200-5/P2 | | | |
8440-2020 | easYgen-3200-5/P2 | 8440-2052 | easYgen-3200-5/P2 | | | |
8440-2021 | easYgen-3100-1/P2 | 8440-2057 | easYgen-3100-1/P2 | | | |
8440-2094 | MFR2S41B/PSV+A2D06MMBQUSB | 8440-2088 | easYgen-3500XT-P2 | easYgen-3000XT plus ESEPRO required | | |
8440-2099 | MFR2S45B/PSV+D06QFQUSB | 8440-2088 | easYgen-3500XT-P2 | easYgen-3000XT plus ESEPRO required | | |
8440-2102 | MFR2S11B/PSV+A2G01MMBSB | 8440-2088 | easYgen-3500XT-P2 | easYgen-3000XT plus ESEPRO required | | |
8440-2104 | MFR2S41B/PSV+A2G01MMBSB | 8440-2088 | easYgen-3500XT-P2 | easYgen-3000XT plus ESEPRO required | | |
8441-1003 | MFR1110B/VDEW | 8441-1160 | easYprotec-1410-1 | no display or HMI in replacement | | |
8441-1004 | MFR1110B/G59N | 8441-1160 | easYprotec-1410-1 | no display or HMI in replacement, 24VDC only | | |
8441-1005 | MFR1110B/SC | 8440-2150 | LS-521-5 | | | |
8441-1006 | MFR1215B/51V | in easYgen-3000XT included | | Independent time-overcurrent,Ground fault calculated,Inverse time-overcurrent,Inverse time-overcurrent with voltage restraint; Otherwise contact SEG Electronics for MRI3 | | |
8441-1008 | MFR1205B/50-51GN | | | contact SEG Electronics for MRI3 | | |
8441-1009 | MFR1315B/GPX-I | | | consider an easYgen control and consolidate functionality like Sychronization & Loadsharinig | | |
8441-1010 | ESDR405B | | | contact SEG Electronics for MRDT4-2A0AA | | |
8441-1011 | IKN1M/V1 | | | Axiomatic TC-20 thermo couple scanner is functionally close; However communication protocolls don't fit, so you need to upgrade to a new system. | | |
8441-1013 | TUG416B/SU | | | sorry, there is no direct replacement available | | |
8441-1023 | MFR1140B/MP | 8441-1161 | easYprotec-1410-7 | no display or HMI in replacement | | |
8441-1025 | MFR1170M/MP | 8444-1161 | easYprotec-1410-7 | no display or HMI in replacement | | |
8441-1027 | MFR1140B/NU | 8441-1161 | easYprotec-1410-7 | no display or HMI in replacement, 24VDC only | | |
8441-1033 | MFR1345B/GPX | | | consider an easYgen control and consolidate functionality like Sychronization & Loadsharinig | | |
8441-1040 | MFR1345B/IZPM02PSUZQ | | | consider an easYgen control and consolidate functionality like Sychronization & Loadsharinig | | |
8441-1047 | ESDR405TM | | | contact SEG Electronics for MRDT4-2A0AA | | |
8441-1049 | MFR1140B/VDEW | 8441-1161 | easYprotec-1410-7 | no display or HMI in replacement | | |
8441-1052 | MFR1315B/IUIZPMPSRSUUYCZQ | | | consider an easYgen control and consolidate functionality like Sychronization & Loadsharinig | | |
8441-1059 | MFR1140-H0015M/NRUU04 | | | nuclear application; there should be stock based on a last time buy available | | |
8441-1060 | MFR1110-H0015M/NRUU04 | | | nuclear application; there should be stock based on a last time buy available | | |
8441-1061 | MFR1140-H0020M/RUU04 | | | nuclear application; there should be stock based on a last time buy available | | |
8441-1062 | MFR1110B/RUV | 8444-1160 | easYprotec-1410-1 | no display or HMI in replacement | | |
8441-1075 | MFR1311B/GPX-I | | | consider an easYgen control and consolidate functionality like Sychronization & Loadsharinig | | |
8441-1082 | MFR1211B/51V | | | contact SEG Electronics for MRI3 | | |
8441-1083 | MFR1311B/GPX | | | consider an easYgen control and consolidate functionality like Sychronization & Loadsharinig | | |
8441-1084 | MFR1170B/G59 | 8444-1161 | easYprotec-1410-7 | no display or HMI in replacement | | |
8441-1086 | MFR1315B/GPY-I | | | consider an easYgen control and consolidate functionality like Sychronization & Loadsharinig | | |
8441-1087 | MFR1315B/K08 | | | consider an easYgen control and consolidate functionality like Sychronization & Loadsharinig | | |
8441-1092 | MFR1315B/GPY-I-N | | | consider an easYgen control and consolidate functionality like Sychronization & Loadsharinig | | |
8441-1095 | MFR1345B/GPY-I | | | consider an easYgen control and consolidate functionality like Sychronization & Loadsharinig | | |
8441-1097 | MFR1140B/SC | 8440-2152 | LS-511-5/P1 | | | |
8441-1099 | MFR1345B/K08 | | | consider an easYgen control and consolidate functionality like Sychronization & Loadsharinig | | |
8441-1103 | MFR1140B/G59N | 8441-1161 | easYprotec-1410-7 | no display or HMI in replacement, 24VDC only | | |
8441-1104 | MFR1345B/GPX-I | | | consider an easYgen control and consolidate functionality like Sychronization & Loadsharinig | | |
8441-1105 | ESDR401M | | | contact SEG Electronics for MRDT4-2A0AA | | |
8441-1106 | MFR1201B/CP | | | contact SEG Electronics for MRI3 | | |
8441-1108 | MFR1341B/GPX | | | consider an easYgen control and consolidate functionality like Sychronization & Loadsharinig | | |
8441-1109 | MFR1315B/IZPMPSSUUZQ | | | consider an easYgen control and consolidate functionality like Sychronization & Loadsharinig | | |
8441-1110 | MFR1110B/SC+N | 8440-2150 | LS-521-5 | 24VDC only | | |
8441-1111 | MFR1140B/SC+N | 8440-2150 | LS-521-5 | 24VDC only | | |
8441-1112 | MFR1345B/IZPM02PSSUUZQ | | | consider an easYgen control and consolidate functionality like Sychronization & Loadsharinig | | |
8441-1114 | MFR1341B/GP | | | consider an easYgen control and consolidate functionality like Sychronization & Loadsharinig | | |
8441-1126 | MFR1140B/A2NSUUU03 | 8444-1161 | easYprotec-1410-7 | no display or HMI in replacement, no CAN Interface | | |
8441-1127 | TUG412B | | | sorry, there is no direct replacement available | | |
8441-1128 | TUG408B | | | sorry, there is no direct replacement available | | |
8441-1129 | TUG416B/SUSU05 | | | sorry, there is no direct replacement available | | |
8441-1130 | TUG412B/SU | | | sorry, there is no direct replacement available | | |
8441-1131 | TUG412B/SUSU05 | | | sorry, there is no direct replacement available | | |
8441-1132 | MFR1201B/50-51GN | | MRI3 from SEG | Ground fault measured via current transformer; contact SEG Electronics for MRI3 | | |
8441-1133 | TUG416B | | | sorry, there is no direct replacement available | | |
8441-1136 | TUG416B/SU | | | sorry, there is no direct replacement available | | |
8441-1137 | TUG412B/SU | | | sorry, there is no direct replacement available | | |
8441-1141 | TUG408B/SUSU05 | | | sorry, there is no direct replacement available | | |
8441-1145 | TUG408B/SU | | | sorry, there is no direct replacement available | | |
8441-1146 | TUG404B/N-MIRO | | | sorry, there is no direct replacement available | | |
8441-1149 | TUG408B/SUSU05THTH | | | sorry, there is no direct replacement available | | |
8441-1153 | TUG408B/SUTH | | | sorry, there is no direct replacement available | | |
8444-1001 | UMT111B/SU | | | sorry, there is no direct replacement available | | |
8444-1002 | UMT115B/A3SU | | | sorry, there is no direct replacement available | | |
8444-1009 | UMT145B/A3SU | | | sorry, there is no direct replacement available | | |
8444-1014 | MPU1-F-5B/CAN | | | sorry, there is no direct replacement available | | |
8444-1015 | MPU1-F-1B/CAN | | | sorry, there is no direct replacement available | | |
8444-1016 | MPU1-F-5B/MOD | | | sorry, there is no direct replacement available | | |
8444-1019 | UMT115B/A6 | | | sorry, there is no direct replacement available | | |
8444-1022 | UMT111B/A3SU | | | sorry, there is no direct replacement available | | |
8444-1027 | UMT111B/A3SU | | | sorry, there is no direct replacement available | | |
8444-1028 | UMT141B/A6N | | | sorry, there is no direct replacement available | | |
8444-1038 | UMT115B/SU | | | sorry, there is no direct replacement available | | |
8444-1042 | UMT111B/A6NU05 | | | sorry, there is no direct replacement available | | |
8444-1043 | UMT141B/A3SU | | | sorry, there is no direct replacement available | | |
8444-1050 | UMT145B/A3SU | | | sorry, there is no direct replacement available | | |
8444-1051 | UMT115B/A3SU | | | sorry, there is no direct replacement available | | |
8444-1054 | UMT111B/A8 | | | sorry, there is no direct replacement available | | |
8444-1056 | UMT111B/SUU05 | | | sorry, there is no direct replacement available | | |
8444-1057 | UMT145B/A6 | | | sorry, there is no direct replacement available | | |
8444-1068 | UMT111B/A3M04SU | | | sorry, there is no direct replacement available | | |
8444-1069 | UMT111B/A3M04SUU05 | | | sorry, there is no direct replacement available | | |
8444-1084 | UMT171B/A3 | | | sorry, there is no direct replacement available | | |
8445-1001 | GW4M/CAN+MTU4000 | | | no replacement | | |
8445-1002 | GW4M/PROFIBUS+SU02 | 8445-1046 | ESEPRO | | | |
8445-1013 | GW4B/RS232+LDP+MDM02 | | | no replacement | | |
8445-1015 | GW4B/RS422+LDP | | | no replacement | | |
8445-1022 | GW4M/RS232+MOD | | | ProCon X GCP-MG-Gateway | | |
8446-1061 | RP3000XT | 8446-1068 | RP3000XT | | | |
9905-355 | DSLC .5-4.5V, WYE, 120/240V, FULL | 8440-2299 | DSLC-2XT | Ethernet Communication - no LON ! | | |
9905-363 | DSLC +/- 3V, OPEN DELTA, 240V, FULL | 8440-2299 | DSLC-2XT | Ethernet Communication - no LON ! | | |
9905-367 | DSLC .5-4.5V, OPEN DELTA, 120V, FULL | 8440-2299 | DSLC-2XT | Ethernet Communication - no LON ! | | |
9905-373 | DSLC 500HZ PWM, OPEN DELTA, 120V, FULL | 8440-2299 | DSLC-2XT | Ethernet Communication - no LON ! | | |
9905-603 | DSLC, 1-5V, WYE, 120/240, FULL | 8440-2299 | DSLC-2XT | Ethernet Communication - no LON ! | | |
9905-708 | DSLC 1-5V, OPEN DELTA, 120V FULL | 8440-2299 | DSLC-2XT | Ethernet Communication - no LON ! | | |
9905-795 | DSLC, +/-3V, WYE, 120/240, FULL | 8440-2299 | DSLC-2XT | Ethernet Communication - no LON ! | | |
9905-797 | DSLC, +/-3V, OPEN DELTA, 120, FULL | 8440-2299 | DSLC-2XT | Ethernet Communication - no LON ! | | |
9905-799 | DSLC, 500HZ PWM, WYE, 120/240, FULL | 8440-2299 | DSLC-2XT | Ethernet Communication - no LON ! | | |
9907-004 | MSLC, WYE, 120/240 | 8440-2298 | MSLC-2XT | Ethernet Communication - no LON ! | | |
9907-005 | MSLC, OPEN DELTA, 120 | 8440-2298 | MSLC-2XT | Ethernet Communication - no LON ! | | |
9907-006 | MSLC, OPEN DELTA, 240 | 8440-2298 | MSLC-2XT | Ethernet Communication - no LON ! | | |
DB1 | DB1 | No similar item | Speed Module for AMF Controller Types NC3 and NB2 | | | |
DU2624* | DU2-6-24 | 8440-3003 | easYgen-800 Note: EG-800 does not require Ignition speed. | | | |
DU2BUSL81A* | DU2-BUSL8-1A | No similar item | Extension module for DU2 | | | |
DU2BUSL82A* | DU2-BUSL8-2A | No similar item | Extension module for DU2 | | | |
DU2BUSL83A* | DU2-BUSL8-3A | No similar item | Extension module for DU2 | | | |
DU2BUSL84A* | DU2-BUSL8-4A | No similar item | Extension module for DU2 | | | |
ED2824* | ED2-8-24 | No similar item | Extension module for DU2 | | | |
FC1824* | FC1-8-24 | No similar item | Remote signal module for NC3 | | | |
LR20001 | ASG410+B/VJH | 8440-2164 | SPM-D2-1040B | additional easYprotec-1410 required for mains protection | | |
LR20019 | ASG410+B | 8440-2164 | SPM-D2-1040B | | | |
LR20021 | ESDR401TB | | | contact SEG Electronics for MRDT4-2A0AA | | |
LR20025 | MFR1375M/RSu03UV | 8444-1093 | MFR300-75M/SU03 | | | |
LR20041 | ASG410+BFU | 8440-2164 | SPM-D2-1040B | | | |
LR20042 | ASG410+B | 8440-2164 | SPM-D2-1040B | | | |
LR20049 | ASG410+M | 8440-2164 | SPM-D2-1040B | DIN Rail Brackets 8923-1023 required | | |
LR20071 | ASG410+B/VJH | 8440-2164 | SPM-D2-1040B | additional easYprotec-1410 required for mains protection | | |
LR20072 | ASG410+B | 8440-2164 | SPM-D2-1040B | | | |
LR20073 | ASG410+BF | 8440-2164 | SPM-D2-1040B | | | |
LR20092 | ASG410+B/QF | 8440-2171 | SPM-D2-1040B/X | AVR +/-5V f+/-relays | | |
LR20111 | ASG410+40B/YB | 8440-2176 | SPM-D2-1040B/YB | | | |
LR20113 | ASG421+B/FHJLPRUVW | 8440-2317 | LS-6XT-P2 | LS-6XT-P2 configured for active synchronization, consider 8446-1071 easYview HMI Display | | |
LR20137 | UMT115B/A3SUU02 | | | sorry, there is no direct replacement available | | |
LR20138 | ASG422+B/HJRUV | 8440-2317 | LS-6XT-P2 | LS-6XT-P2 configured for active synchronization, consider 8446-1071 easYview HMI Display | | |
LR20139 | ASG422+B/FHJRUV | 8440-2317 | LS-6XT-P2 | LS-6XT-P2 configured for active synchronization, consider 8446-1071 easYview HMI Display | | |
LR20152 | ASG410+10B/YA | 8440-2167 | SPM-D2-1010B/YB | | | |
LR20170 | ASG410+10B/YB | 8440-2167 | SPM-D2-1010B/YB | | | |
LR20171 | GW4M/RS232+LDP | 8445-1046 | ESEPRO | no replacement | | |
LR20185 | ASG421+B/DIMAG TYP 50 | 8440-2317 | LS-6XT-P2 | LS-6XT-P2 configured for active synchronization, consider 8446-1071 easYview HMI Display | | |
LR20186 | ASG420+B/HJV | 8440-2317 | LS-6XT-P2 | LS-6XT-P2 configured for active synchronization, consider 8446-1071 easYview HMI Display | | |
LR20187 | ASG411+M/A22HJRUV | 8440-2281 | easYgen-3200XT-P1-LITE | | | |
LR20197 | UMT145B/A4 | | | sorry, there is no direct replacement available | | |
LR20206 | ASG410+B/QFK04 | 8440-2171 | SPM-D2-1040B/X | AVR +/-5V | | |
LR20213 | UMT115B/A6N | | | sorry, there is no direct replacement available | | |
LR20228 | GW4M/PROFIBUS+DPSLAVE | 8445-1046 | ESEPRO | | | |
LR20238 | ASG421+B | 8440-2317 | LS-6XT-P2 | LS-6XT-P2 configured for active synchronization, consider 8446-1071 easYview HMI Display | | |
LR20326 | ASG411+B | 8440-2169 | SPM-D2-1145B/LSXR | | | |
LR20338 | ST2000N | 8440-2252 | easYgen-600 | ST2000N was a modified AMG3 without generator functionality for Diesel pumps. Use the HMI Editor to show AC values | | |
LR20344 | ASG411+B | 8440-2169 | SPM-D2-1145B/LSXR | change of CT to 1A required | | |
LR20349 | ASG4E3-400 | 8440-2164 | SPM-D2-1040B | DIN Rail Brackets 8923-1023 required | | |
LR20350 | ASG410+10B/YB | 8440-2167 | SPM-D2-1010B/YB | | | |
LR20354 | AMG3S45B/NEB | 8440-2281 | easYgen-3200XT-P1-LITE | | | |
LR20403 | ASG410+B/HJQFV | 8440-2164 | SPM-D2-1040B | AVR +/-5V and easYprotec-1410 for mains protection | | |
LR20406 | MFR1140B/G59 | 8441-1161 | easYprotec-1410-7 | no display or HMI in replacement | | |
LR20407 | ASG421+B/FHJRUV | 8440-2317 | LS-6XT-P2 | LS-6XT-P2 configured for active synchronization, consider 8446-1071 easYview HMI Display | | |
LR20410 | ASG411+B/FHJPUV | 8440-2281 | easYgen-3200XT-P1-LITE | | | |
LR20411 | UMT111B/A3 | | | sorry, there is no direct replacement available | | |
LR20413 | IKN 1M/A1B0C1D3I1 | X | | Axiomatic TC-20 thermo couple scanner is functionally close; However communication protocolls don't fit, so you need to upgrade to a new system. | | |
LR20417 | ASG410+40B/YB | 8440-2176 | SPM-D2-1040B/YB | | | |
LR20436 | ASG421+B/DIMAG TYP 30 | 8440-2317 | LS-6XT-P2 | LS-6XT-P2 configured for active synchronization, consider 8446-1071 easYview HMI Display | | |
LR20440 | ASG411+B/HJRV | 8440-2169 | SPM-D2-1145B/LSXR | easYprotec-1410 for mains protection | | |
LR20445 | ASG421+B/HJPRV | 8440-2317 | LS-6XT-P2 | LS-6XT-P2 configured for active synchronization, consider 8446-1071 easYview HMI Display | | |
LR20451 | ASG410+10M/YB | 8440-2167 | SPM-D2-1010B/YB | DIN Rail Brackets 8923-1023 required | | |
LR20455 | ASG421+B/DIMAG TYP 30 MIT YP | 8440-2317 | LS-6XT-P2 | LS-6XT-P2 configured for active synchronization, consider 8446-1071 easYview HMI Display | | |
LR20459 | ESDR401B | | | contact SEG Electronics for MRDT4-2A0AA | | |
LR20475 | AMG3A45B/N1PB-IN20 | 8440-2082 | easYgen-3200XT | | | |
LR20478 | ASG411+B/FHJRUV | 8440-2281 | easYgen-3200XT-P1-LITE | | | |
LR20485 | ASG410+M | 8440-2164 | SPM-D2-1040B | DIN Rail Brackets 8923-1023 required | | |
LR20508 | ASG421+B/A12FPRUXZ | 8440-2317 | LS-6XT-P2 | LS-6XT-P2 configured for active synchronization, consider 8446-1071 easYview HMI Display | | |
LR20509 | ASG410+10B/NYB | 8440-2177 | SPM-D2-1010B/NYB | | | |
LR20530 | ASG4E3-100 | 8440-2166 | SPM-D2-1010B | DIN Rail Brackets 8923-1023 required | | |
LR20547 | ASG411+B/HJV | 8440-2169 | SPM-D2-1145B/LSXR | easYprotec-1410 for mains protection | | |
LR20582 | AMG3S45B/N2PB | 8440-2082 | easYgen-3200XT | | | |
LR20583 | AMG3S45B/NEB-QF | 8440-2281 | easYgen-3200XT-P1-LITE | | | |
LR20590 | ESDR405M | | | contact SEG Electronics for MRDT4-2A0AA | | |
LR20597 | ASG411+B/A22COPWXZ | 8440-2082 | easYgen-3200XT | | | |
LR20602 | ASG421+B/A11FPRUXZ | 8440-2317 | LS-6XT-P2 | LS-6XT-P2 configured for active synchronization, consider 8446-1071 easYview HMI Display | | |
LR20610 | MFR1110B/NU | 8441-1161 | easYprotec-1410-7 | no display or HMI in replacement, 24VDC only | | |
LR20616 | ESDR401TM | | | contact SEG Electronics for MRDT4-2A0AA | | |
LR20665 | ASG410+B/G | 8440-2170 | SPM-D2-10B/PSY5-FU-D | | | |
LR20684 | ASG411+B/R | 8440-2169 | SPM-D2-1145B/LSXR | | | |
LR20685 | MFR2S45B/PSV | 8440-2082 | easYgen-3200XT | | | |
LR20705 | ASG410+B/VJH | 8440-2164 | SPM-D2-1040B | additional easYprotec-1410 required for mains protection | | |
LR20710 | MFR2S45B/EVC1 | | | customized, there should be stock based on a last time buy available | | |
LR20711 | AMG2S45B/A2EVC1 | | | customized, there should be stock based on a last time buy available | | |
LR20722 | ASG421+B/CHJPRV | 8440-2317 | LS-6XT-P2 | LS-6XT-P2 configured for active synchronization, consider 8446-1071 easYview HMI Display | | |
LR20767 | AMG3S45B/N2PB-X-ELIN | 8440-2082 | easYgen-3200XT | | | |
LR20791 | ASG420+B | 8440-2317 | LS-6XT-P2 | LS-6XT-P2 configured for active synchronization, consider 8446-1071 easYview HMI Display | | |
LR20796 | ASG421+B/PSV | 8440-2317 | LS-6XT-P2 | LS-6XT-P2 configured for active synchronization, consider 8446-1071 easYview HMI Display | | |
LR20819 | IKN1M/V2 | X | | Axiomatic TC-20 thermo couple scanner is functionally close; However communication protocolls don't fit, so you need to upgrade to a new system. | | |
LR20840 | ASG4E3-100 | 8440-2166 | SPM-D2-1010B | DIN Rail Brackets 8923-1023 required | | |
LR20851 | AMG3S45B/N2PB-SFT4W- | 8440-2082 | easYgen-3200XT | replacement has only 3AIs | | |
LR20856 | GW4B/RS232+DK3964 | 8445-1046 | ESEPRO | Siemens S5 protocol - replace with easYgen3000XT and ESEPRO | | |
LR20863 | ASG410+40B/YBYU | 8440-2176 | SPM-D2-1040B/YB | | | |
LR20928 | ASG421+B/CPRX | 8440-2317 | LS-6XT-P2 | LS-6XT-P2 configured for active synchronization, consider 8446-1071 easYview HMI Display | | |
LR20929 | AMG3S45B/N2PB-QFQU | 8440-2082 | easYgen-3200XT | | | |
LR20945 | ASG410+40B/YBN | 8440-2189 | SPM-D2-1040B/NYB | | | |
LR20949 | UMT145B/A3 | | | sorry, there is no direct replacement available | | |
LR20988 | MFR2S45B/PSV+QUSB | 8440-2088 | easYgen-3500XT-P2 | easYgen-3000XT plus ESEPRO required | | |
LR20994 | AMG3S45B/N1PB-A2T4WO | 8440-2082 | easYgen-3200XT | replacement has only 3AIs | | |
LR20995 | MFR32S11B/CDHI1I3I4JR1SFT7VZE | 8440-2088 | easYgen-3500XT-P2 | | | |
LR21005 | ASG410+B | 8440-2164 | SPM-D2-1040B | | | |
LR21011 | ASG410+40B/YBN | 8440-2189 | SPM-D2-1040B/NYB | | | |
LR21024 | ASG411+B/Z | 8440-2169 | SPM-D2-1145B/LSXR | | | |
LR21035 | MFR1345B/GP | | | consider an easYgen control and consolidate functionality like Sychronization & Loadsharinig | | |
LR21040 | AMG2S45B/N1PB-QFSFT7XZE | 8440-2088 | easYgen-3500XT-P2 | | | |
LR21046 | AMG3S45B/N1PB | 8440-2082 | easYgen-3200XT | | | |
LR21047 | ASG410+B/N | 8440-2175 | SPM-D2-1040B/N | | | |
LR21050 | MFR1345B/NPM | | | reverse power relay | | |
LR21059 | ASG411+B/A22HJRUVFCQU | 8440-2281 | easYgen-3200XT-P1-LITE | | | |
LR21060 | ASG410+10B/YA | 8440-2167 | SPM-D2-1010B/YB | | | |
LR21068 | ASG421+B/HJPVX | 8440-2317 | LS-6XT-P2 | LS-6XT-P2 configured for active synchronization, consider 8446-1071 easYview HMI Display | | |
LR21074 | ASG410+B/VJH | 8440-2164 | SPM-D2-1040B | easYprotec-1410 for mains protection | | |
LR21077 | ASG411+M/PRX | 8440-2169 | SPM-D2-1145B/LSXR | | | |
LR21086 | AMG2S45B/N2PB-SEC400 | | | customized; no replacement | | |
LR21087 | AMG3S45B/N1PB-EDF | 8440-2082 | easYgen-3200XT | | | |
LR21092 | UMT145B/SU | | | sorry, there is no direct replacement available | | |
LR21107 | AMG3S45B/NEB-EWA001 | 8440-2281 | easYgen-3200XT-P1-LITE | additional IKD1M required | | |
LR21121 | MFR2S15B/PSVT+A2I3SB | 8440-2088 | easYgen-3500XT-P2 | different Modbus protocol | | |
LR21127 | AMG3S45B/N2PB-OQUSBS | 8440-2082 | easYgen-3200XT | | | |
LR21131 | UMT145B/NSU | | | sorry, there is no direct replacement available | | |
LR21132 | AMG3S45B/N2PB-QFT4 | 8440-2082 | easYgen-3200XT | replacement has only 3AIs | | |
LR21144 | ASG411+M/QFW | 8440-2169 | SPM-D2-1145B/LSXR | 0-10V speed bias | | |
LR21148 | ASG411+M/VJHPRX | 8440-2281 | easYgen-3200XT-P1-LITE | | | |
LR21151 | MFR2S15B/PSV+A2SUY02 | 8440-2082 | easYgen-3200XT | Modbus protocol is not same! | | |
LR21154 | ASG410+M/VJH | 8440-2164 | SPM-D2-1040B | easYprotec-1410 for mains protection&DIN Rail Brackets 8923-1023 required | | |
LR21156 | AMG3S45B/N1PB-SFT4W- | 8440-2082 | easYgen-3200XT | replacement has only 3AIs | | |
LR21159 | UMT141B/A6 | | | sorry, there is no direct replacement available | | |
LR21289 | AMG3S45B/NEB | 8440-2281 | easYgen-3200XT-P1-LITE | | | |
LR21296 | UMT111B/A6 | | | sorry, there is no direct replacement available | | |
LR21297 | ASG410+B/VJH-Y01 | 8440-2164 | SPM-D2-1040B | be careful! synchronization over transformer | | |
LR21300 | AMG2S15B/N2PB-A2QFQUX | 8440-2088 | easYgen-3500XT-P2 | | | |
LR21302 | MFR2A45B/PSV+A2T2 | 8440-2082 | easYgen-3200XT | EPU-100 required | | |
LR21305 | MFR2S15B/PSV+A2I3SB | 8440-2088 | easYgen-3500XT-P2 | different Modbus protocol | | |
NB218* | NB2-1-8 | 8440-3005 | easYgen-1800 + 1x IKD or easYgen 2500 + 1x IKD | | | |
NB2RS232* | NB2-RS232 | | | not needed if easYgen-x800 applied | | |
NC3116 | NC3-1-16 | 8440-2281 | easYgen-3200XT-P1-LITE + 2x IKD 1 | | | |
NC318 | NC3-1-8 | 8440-2281 | easYgen-3200XT-P1-LITE + 1x IKD 1 | | | |
NC3216 | NC3-2-16 | 8440-3005 | easYgen-800 +2x IKD 1 | | | |
NC328 | NC3-2-8 | 8440-3005 | easYgen-800 + 1x IKD 1 Note: Ignition speed via DI not possible | | | |
NC3316 | NC3-3-16 | No similar item | Pump set control application | | | |
NC3RS232 | NC3-RS232 | 5417-557 | COMMUNICATION DEVICE-DPC if easYgen-2500 applied | 5417-1251 DPC USB | | |
PSY4/5AP | PSY4/5-AP | 8440-2170 | SPM-D2-10B/PSY5-FU-D | | | |
SY140050 | SY1-400-50 | 8440-2170 | SPM-D2-10B/PSY5-FU-D | | | |
SYSP40050 | SY-SP-400-50 | 8440-2170 | SPM-D2-10B/PSY5-FU-D | | | |
LR20018 | SKG112-0 | 8440-2166 | SPM-D2-1010B | DIN Rail Brackets 8923-1023 required; additional 24 V power supply required | | |
LR20043 | SKG141-0 | 8440-2164 | SPM-D2-1040B | DIN Rail Brackets 8923-1023 required; additional 24 V power supply required | | |
LR20056 | SKG111-0 | 8440-2166 | SPM-D2-1010B | DIN Rail Brackets 8923-1023 required; additional 24 V power supply required | | |
LR20057 | SKG121-0 | 8440-2164 | SPM-D2-1040B | DIN Rail Brackets 8923-1023 required; additional 24 V power supply required | | |
LR20200 | SKG142-0 | 8440-2164 | SPM-D2-1040B | DIN Rail Brackets 8923-1023 required; additional 24 V power supply required | | |
LR20301 | SKG112-0 | 8440-2166 | SPM-D2-1010B | DIN Rail Brackets 8923-1023 required; additional 24 V power supply required | | |
LR20302 | SKG121-0 | 8440-2164 | SPM-D2-1040B | DIN Rail Brackets 8923-1023 required; additional 24 V power supply required | | |
LR20303 | SKG122-0 | 8440-2164 | SPM-D2-1040B | DIN Rail Brackets 8923-1023 required; additional 24 V power supply required | | |
LR20304 | SKG141-0 | 8440-2164 | SPM-D2-1040B | DIN Rail Brackets 8923-1023 required; additional 24 V power supply required | | |
LR20305 | SKG142-0 | 8440-2164 | SPM-D2-1040B | DIN Rail Brackets 8923-1023 required; additional 24 V power supply required | | |
LR20316 | SKG111-0 | 8440-2166 | SPM-D2-1010B | DIN Rail Brackets 8923-1023 required; additional 24 V power supply required | | |
LR20382 | SKG121-SS | 8440-2164 | SPM-D2-1040B | DIN Rail Brackets 8923-1023 required; additional 24 V power supply required | | |
LR21004 | SKG111-E | 8440-2166 | SPM-D2-1010B | DIN Rail Brackets 8923-1023 required; additional 24 V power supply required | | |
8440-1526 | SKG121-E | 8440-2164 | SPM-D2-1040B | DIN Rail Brackets 8923-1023 required; additional 24 V power supply required | | |
LR20650 | GCP-3215B/X | 8440-2088 | easYgen-3200XT-P2 | | | |
LR20776 | GCP-3145B/R | 8440-2082 | easYgen-3200XT | | | |
LR20777 | GCP-3245B/A | 8440-2082 | easYgen-3200XT | | | |
LR20784 | GCP-3115B/X | 8440-2088 | easYgen-3200XT-P2 | | | |
LR20785 | GCP-3115B/R | 8440-2082 | easYgen-3200XT | | | |
LR20793 | GCP-3215B/R | 8440-2082 | easYgen-3200XT | | | |
LR21143 | GCP-3245B/X | 8440-2088 | easYgen-3200XT-P2 | | | |
5448-866 | GCP-3215B/X | 8440-2088 | easYgen-3200XT-P2 | | | |
5448-867 | GCP-3215B/R | 8440-2082 | easYgen-3200XT | | | |
5448-868 | GCP-3115B/X | 8440-2088 | easYgen-3200XT-P2 | | | |
5448-869 | GCP-3115B/R | 8440-2082 | easYgen-3200XT | | | |
5448-907 | GCP-3245B/A | 8440-2082 | easYgen-3200XT | | | |
5448-908 | GCP-3145B/R | 8440-2082 | easYgen-3200XT | | | |
8440-1080 | GCP-3145B/SFT7 | 8440-2088 | easYgen-3200XT-P2 | | | |
8440-1083 | GCP-3245B/QFSCSC01SF | 8440-2082 | easYgen-3200XT | | | |
8440-1086 | GCP-3055B/T4ZE | 8440-2281 | easYgen-3200XT-P1-LITE | | | |
8440-1090 | GCP-3215B/A2IN20QFQUSBSFT7XZEZS | 8440-2088 | easYgen-3200XT-P2 | | | |
8440-1111 | GCP-3145B/SCSCM01SF | 8440-2082 | easYgen-3200XT | | | |
8440-1189 | GCP-3215B/QSF | 8440-2088 | easYgen-3200XT-P2 | | | |
8440-1192 | GCP-3215B/A2QFSFT7XZEZS | 8440-2088 | easYgen-3200XT-P2 | | | |
8440-1194 | GCP-3115B/A2SFT7X | 8440-2088 | easYgen-3200XT-P2 | | | |
8440-1199 | GCP-3115B/U | 8440-2088 | easYgen-3200XT-P2 | | | |
8440-1201 | GCP-3245B/A2QSFT402ZEZS | 8440-2088 | easYgen-3200XT-P2 | | | |
8440-1264 | GCP-3145B/QSF | 8440-2082 | easYgen-3200XT | | | |
8440-1271 | GCP-3215B/A2QSCSCMSFT7X | 8440-2088 | easYgen-3200XT-P2 | | | |
8440-1302 | GCP-3055B/SFT4ZE | 8440-2088 | easYgen-3200XT-P2 | | | |
8440-1311 | GCP-3145B/QSFZS | 8440-2082 | easYgen-3200XT | | | |
8440-1315 | GCP-3115B/A2QSB03SFZEZS | 8440-2082 | easYgen-3200XT | CAT CCM not supported | | |
8440-1321 | GCP-3145B/U | 8440-2088 | easYgen-3200XT-P2 | | | |
8440-1322 | GCP-3215B/A2IN20QSBSFT7XZEZS | 8440-2088 | easYgen-3200XT-P2 | | | |
8440-1334 | GCP-3145B/A2D03QSFT7XZEZS | 8440-2088 | easYgen-3200XT-P2 | | | |
8440-1342 | GCP-3115B/SCSCM01SFT7 | 8440-2088 | easYgen-3200XT-P2 | | | |
8440-1350 | GCP-3051B/T4ZE | 8440-2281 | easYgen-3200XT-P1-LITE | | | |
8440-1351 | GCP-3115B/A2IN20QSBSFT7XZEZS | 8440-2088 | easYgen-3200XT-P2 | | | |
8440-1355 | GCP-3245B/A2SFT7X | 8440-2088 | easYgen-3200XT-P2 | | | |
8440-1378 | GCP-3145B/QSC03SFT7 | 8440-2088 | easYgen-3200XT-P2 | | | |
8440-1423 | GCP-3115B/A2L4QSBSFT7XZEZS | 8440-2088 | easYgen-3200XT-P2 | LS4 not supported | | |
8440-1426 | GCP-3245B/U | 8440-2088 | easYgen-3200XT-P2 | | | |
8440-1427 | GCP-3245B/QSF | 8440-2082 | easYgen-3200XT | | | |
8440-1429 | GCP-3145B/A2L4SBCCM01SFT7XZE | 8440-2088 | easYgen-3200XT-P2 | LS4 not supported | | |
8440-1454 | GCP-3115B/A2L4QSC02SFT701ZEZS | 8440-2088 | easYgen-3200XT-P2 | LS4 not supported | | |
8440-1456 | GCP-3215B/A2QSC06SFT701ZEZS | 8440-2088 | easYgen-3200XT-P2 | LS4 not supported | | |
8440-1459 | GCP-3145B/A2L4QSBCCM01SFT701ZE | 8440-2088 | easYgen-3200XT-P2 | LS4 not supported | | |
8440-1513 | GCP-3115B/A2L4K09QSBSFT708 | 8440-2088 | easYgen-3200XT-P2 | LS4 not supported | | |
8440-1515 | GCP-3245B/A2D03QSFT701ZEZS | 8440-2088 | easYgen-3200XT-P2 | LS4 not supported | | |
8440-1518 | GCP-3211B/A2QSC07SFT703ZEZS | 8440-2088 | easYgen-3200XT-P2 | LS4 not supported | | |
8440-1521 | GCP-3145B/A2L4QSC02SFT701ZEZS | 8440-2088 | easYgen-3200XT-P2 | LS4 not supported | | |
8440-1525 | GCP-3211B/X | 8440-2088 | easYgen-3200XT-P2 | LS4 not supported | | |
8440-1532 | GCP-3115B/QSC04SFT7ZE | 8440-2088 | easYgen-3200XT-P2 | LS4 not supported | | |
8440-1543 | GCP-3145B/A2L4QSC06SFT701ZE | 8440-2088 | easYgen-3200XT-P2 | LS4 not supported | | |
8440-1547 | GCP-3241B/X | 8440-2088 | easYgen-3200XT-P2 | LS4 not supported | | |
8440-1548 | GCP-3111B/BPD | 8440-2082 | easYgen-3200XT | | | |
8440-1549 | GCP-3141B/BPD | 8440-2082 | easYgen-3200XT | | | |
8440-1550 | GCP-3115B/BPD | 8440-2082 | easYgen-3200XT | | | |
8440-1551 | GCP-3145B/BPD | 8440-2082 | easYgen-3200XT | | | |
8440-1552 | GCP-3111B/XPD | 8440-2088 | easYgen-3200XT-P2 | LS4 not supported | | |
8440-1553 | GCP-3141B/XPD | 8440-2088 | easYgen-3200XT-P2 | LS4 not supported | | |
8440-1554 | GCP-3115B/XPD | 8440-2088 | easYgen-3200XT-P2 | LS4 not supported | | |
8440-1555 | GCP-3145B/XPD | 8440-2088 | easYgen-3200XT-P2 | LS4 not supported | | |
8440-1557 | GCP-3141B/XPQ | 8440-2088 | easYgen-3200XT-P2 | LS4 not supported | | |
8440-1564 | GCP-3211B/BPD | 8440-2082 | easYgen-3200XT | | | |
8440-1565 | GCP-3241B/BPD | 8440-2082 | easYgen-3200XT | | | |
8440-1566 | GCP-3215B/BPD | 8440-2082 | easYgen-3200XT | | | |
8440-1567 | GCP-3245B/BPD | 8440-2082 | easYgen-3200XT | | | |
8440-1568 | GCP-3211B/XPD | 8440-2088 | easYgen-3200XT-P2 | LS4 not supported | | |
8440-1569 | GCP-3241B/XPD | 8440-2088 | easYgen-3200XT-P2 | LS4 not supported | | |
8440-1570 | GCP-3215B/XPD | 8440-2088 | easYgen-3200XT-P2 | LS4 not supported | | |
8440-1571 | GCP-3245B/XPD | 8440-2088 | easYgen-3200XT-P2 | LS4 not supported | | |
8440-1607 | GCP-3111B/BPQ | 8440-2082 | easYgen-3200XT | | | |
8440-1608 | GCP-3141B/BPQ | 8440-2082 | easYgen-3200XT | | | |
8440-1611 | GCP-3211B/BPQ | 8440-2082 | easYgen-3200XT | | | |
8440-1613 | GCP-3215B/BPQ | 8440-2082 | easYgen-3200XT | | | |
8440-1658 | GCP-3145B/XPD+SC10 | 8440-2088 | easYgen-3200XT-P2 | LS4 not supported | | |
8440-1675 | GCP-3245B/XPD+SC10 | 8440-2088 | easYgen-3200XT-P2 | LS4 not supported | | |
8440-1680 | GCP-3245B/XPQ | 8440-2088 | easYgen-3200XT-P2 | LS4 not supported | | |
8440-1682 | GCP-3211B/XPD+SC10 | 8440-2088 | easYgen-3200XT-P2 | LS4 not supported | | |
8440-1684 | GCP-3145B/BPD+SC10 | 8440-2088 | easYgen-3200XT-P2 | LS4 not supported | | |
8440-1685 | GCP-3145B/BPQ+SC10 | 8440-2088 | easYgen-3200XT-P2 | LS4 not supported | | |
8440-1689 | GCP-3115B/L4SC10SFT711ZS | 8440-2088 | easYgen-3200XT-P2 | LS4 not supported | | |
8440-1719 | GCP-3141B/SC06SFT711ZS | 8440-2088 | easYgen-3200XT-P2 | LS4 not supported | | |
8440-1720 | GCP-3145B/BPQ+A2L4T704ZE | 8440-2088 | easYgen-3200XT-P2 | LS4 not supported | | |
8440-1725 | GCP-3245B/XPQ+Y07 | 8440-2088 | easYgen-3200XT-P2 | LS4 not supported | | |
8440-1726 | GCP-3245B/BPD+A2T703 | 8440-2088 | easYgen-3200XT-P2 | LS4 not supported | | |
8440-1753 | GCP-3245B/BPQ+A2T715ZE | 8440-2088 | easYgen-3200XT-P2 | LS4 not supported | | |
8440-1759 | GCP-3245B/A2SC06SFT714TZTZ01ZEZS-EWA003 | 8440-2088 | easYgen-3200XT-P2 | LS4 not supported | | |
8440-1760 | GCP-3245B/XPQ+SC10 | 8440-2088 | easYgen-3200XT-P2 | LS4 not supported | | |
8440-1789 | GCP-3245B/A2K20QSC07T701ZE | 8440-2088 | easYgen-3200XT-P2 | LS4 not supported | | |
8440-1825 | GCP-3245B/XPQ+K23 | 8440-2088 | easYgen-3200XT-P2 | LS4 not supported | | |
8440-1847 | GCP-3245/BPQ+A2K01M03T717ZE | 8440-2088 | easYgen-3200XT-P2 | LS4 not supported | | |
8440-1882 | GCP-3245/BPQ+A2K01M03T717ZE | 8440-2088 | easYgen-3200XT-P2 | LS4 not supported | | |
8440-1895 | GCP-3245B/BPQ | 8440-2082 | easYgen-3200XT | | | |
LR20702 | GCP-2215B/X | 8440-2082 | easYgen-3200XT | | | |
LR20806 | GCP-2115B/R | 8440-2082 | easYgen-3200XT | | | |
LR20807 | GCP-2015B/X | 8440-2082 | easYgen-3200XT | | | |
LR20882 | GCP-2215B/R | 8440-2082 | easYgen-3200XT | | | |
LR20883 | GCP-2215B/B | 8440-2082 | easYgen-3200XT | | | |
LR20884 | GCP-2115B/B | 8440-2082 | easYgen-3200XT | | | |
LR20885 | GCP-2115B | 8440-2082 | easYgen-3200XT | | | |
LR20886 | GCP-2015B/B | 8440-2281 | easYgen-3200XT-P1-LITE | | | |
LR20887 | GCP-2015B | 8440-2281 | easYgen-3200XT-P1-LITE | | | |
LR20958 | GCP-2115B/X | 8440-2082 | easYgen-3200XT | | | |
LR21064 | GCP-2245B/LS | 8440-2082 | easYgen-3200XT | | | |
LR21104 | GCP-2245B/LSX | 8440-2082 | easYgen-3200XT | | | |
LR21111 | GCP-2245B/LSR | 8440-2082 | easYgen-3200XT | | | |
LR21112 | GCP-2145B/LSR | 8440-2082 | easYgen-3200XT | | | |
LR21113 | GCP-2145B/LS | 8440-2082 | easYgen-3200XT | | | |
LR21114 | GCP-2045B/LSX | 8440-2082 | easYgen-3200XT | | | |
LR21115 | GCP-2045B/LS | 8440-2082 | easYgen-3200XT | | | |
LR21307 | GCP-21A15B/A2QFT4X | 8440-2082 | easYgen-3200XT | EPU-100 required | | |
5448-870 | GCP-2215B/X | 8440-2082 | easYgen-3200XT | | | |
5448-871 | GCP-2215B/R | 8440-2082 | easYgen-3200XT | | | |
5448-872 | GCP-2215B/B | 8440-2082 | easYgen-3200XT | | | |
5448-873 | GCP-2115B/X | 8440-2082 | easYgen-3200XT | | | |
5448-874 | GCP-2115B/R | 8440-2082 | easYgen-3200XT | | | |
5448-875 | GCP-2115B/B | 8440-2082 | easYgen-3200XT | | | |
5448-876 | GCP-2115B | 8440-2082 | easYgen-3200XT | | | |
5448-877 | GCP-2015B/X | 8440-2281 | easYgen-3200XT-P1-LITE | | | |
5448-878 | GCP-2015B/B | 8440-2281 | easYgen-3200XT-P1-LITE | | | |
5448-879 | GCP-2015B | 8440-2281 | easYgen-3200XT-P1-LITE | | | |
5448-913 | GCP-2245B/LSR | 8440-2082 | easYgen-3200XT | | | |
5448-914 | GCP-2245B/LS | 8440-2082 | easYgen-3200XT | | | |
5448-915 | GCP-2145B/LSR | 8440-2082 | easYgen-3200XT | | | |
5448-916 | GCP-2145B/LS | 8440-2082 | easYgen-3200XT | | | |
5448-917 | GCP-2045B/LSX | 8440-2281 | easYgen-3200XT-P1-LITE | | | |
5448-918 | GCP-2045B/LS | 8440-2281 | easYgen-3200XT-P1-LITE | | | |
8440-1011 | GCP-2245B/LSX | 8440-2082 | easYgen-3200XT | | | |
8440-1012 | GCP-2245B/LSB | 8440-2082 | easYgen-3200XT | | | |
8440-1013 | GCP-2145B/LSX | 8440-2082 | easYgen-3200XT | | | |
8440-1014 | GCP-2145B/LSB | 8440-2082 | easYgen-3200XT | | | |
8440-1038 | GCP-2045B/T2 | 8440-2082 | easYgen-3200XT | | | |
8440-1052 | GCP-2215B/LSR | 8440-2082 | easYgen-3200XT | | | |
8440-1061 | GCP-2245B/IN20OSFW | 8440-2082 | easYgen-3200XT | | | |
8440-1103 | GCP-2215B/LSB | 8440-2082 | easYgen-3200XT | | | |
8440-1121 | GCP-2245B/OQFSFW | 8440-2082 | easYgen-3200XT | | | |
8440-1209 | GCP-2245B/OQFQF01SFW | 8440-2082 | easYgen-3200XT | | | |
8440-1295 | GCP-2115B/A2IN20OQFQUSFT4WX | 8440-2082 | easYgen-3200XT | | | |
8440-1333 | GCP-2145B/X | 8440-2082 | easYgen-3200XT | | | |
8440-1346 | GCP-2115B/LSR | 8440-2082 | easYgen-3200XT | | | |
8440-1367 | GCP-2245B/LSX | 8440-2082 | easYgen-3200XT | | | |
8440-1368 | GCP-2245B/LSX | 8440-2082 | easYgen-3200XT | | | |
8440-1369 | GCP-2245B/LSX | 8440-2082 | easYgen-3200XT | | | |
8440-1457 | GCP-2045B | 8440-2281 | easYgen-3200XT-P1-LITE | | | |
8440-1522 | GCP-21A15B/A2QFSBT4X | 8440-2082 | easYgen-3200XT | | | |
8440-1530 | GCP-2245B/LSR | 8440-2082 | easYgen-3200XT | | | |
8440-1541 | GCP-2115B/LSB | 8440-2082 | easYgen-3200XT | | | |
8440-1581 | GCP-2015B/LS | 8440-2082 | easYgen-3200XT | | | |
8440-1582 | GCP-2045B/B | 8440-2281 | easYgen-3200XT-P1-LITE | | | |
8440-1583 | GCP-2045B/X | 8440-2281 | easYgen-3200XT-P1-LITE | | | |
8440-1584 | GCP-2015B/LSX | 8440-2082 | easYgen-3200XT | | | |
8440-1585 | GCP-2145B | 8440-2082 | easYgen-3200XT | | | |
8440-1586 | GCP-2115B/LS | 8440-2082 | easYgen-3200XT | | | |
8440-1587 | GCP-2115B/LSX | 8440-2082 | easYgen-3200XT | | | |
8440-1588 | GCP-2215B | 8440-2082 | easYgen-3200XT | | | |
8440-1589 | GCP-2245B | 8440-2082 | easYgen-3200XT | | | |
8440-1590 | GCP-2215B/LS | 8440-2082 | easYgen-3200XT | | | |
8440-1591 | GCP-2215B/LSX | 8440-2082 | easYgen-3200XT | | | |
8440-1676 | GCP-2245B/OQFSFW | 8440-2082 | easYgen-3200XT | | | |
8440-1693 | GCP-21A15B/A2QFSBT4WX | 8440-2082 | easYgen-3200XT | EPU-100 required | | |
8440-1728 | GCP-2145B/OQFSFT4W | 8440-2082 | easYgen-3200XT | | | |
8440-1830 | GCP-2115B/OQFSFT4W | 8440-2082 | easYgen-3200XT | | | |
8440-1896 | GCP-2245B/LS | 8440-2082 | easYgen-3200XT | | | |
8444-1065 | MFR300-71M/WK0200 | 8444-1104 | MFR300-71M/K42 | | | |
8444-1066 | MFR300-75M/WK0200 | 8444-1092 | MFR300-75M | | | |
8444-1067 | MFR300-75M/WK0300 | 8444-1092 | MFR300-75M | | | |
8444-1072 | MFR300-11M/WK0200 | 8444-1089 | MFR300-11M | | | |
8444-1077 | MFR300-71M/WK0200 | 8444-1091 | MFR300-71M | | | |
8444-1078 | MFR300-75M/WK0500 | 8444-1093 | MFR300-75M/SU03 | | | |
8444-1076 | MFR300-15M/WK0200 | 8444-1090 | MFR300-15M | | | |
8444-1079 | MFR300-75M/K28 | 8444-1094 | MFR300-75M/K28 | | | |
8444-1082 | MFR300-71M/WK0600 | 8444-1091 | MFR300-71M | | | |
8444-1085 | MFR300-75M/WK0200 | 8444-1092 | MFR300-75M | | | |
8444-1105 | MFR300-11M/SU03 | 8444-1093 | MFR300-75M/SU03 | 690VAC and ../5A measurement required ! | | |
8444-1106 | MFR300-15M/SU03 | 8444-1093 | MFR300-75M/SU03 | 690VAC measurement required ! | | |
LR20009 | AMG2S41B/A2CDHI1JPR1V | 8440-2082 | easYgen-3200XT | addional IKD1M evenually required | | |
LR20013 | AMG2S45B/SAM VERSION 2.17 | 8440-2088 | easYgen-3500XT-P2 | external AirFuelRatio AFR Control required | | |
LR20022 | AMG2S45-H0018B/N1PB-A2QFQUSFVSW01XZE | 8440-2290 | easYgen-3500XT-P2-RENTAL | not compatible with Synchon Remote Maintance box | | |
LR20028 | AMG2S45B/BEZHIN20JQFR1V | 8440-2082 | easYgen-3200XT | addional IKD1M evenually required | | |
LR20052 | AMG2S45B/A1DEZNOPQFQUR1R2SFT7W | 8440-2088 | easYgen-3500XT-P2 | check analog inputs | | |
LR20055 | AMG2S45B/A2BCDEZHI1JPR1SFT4VXIN20 | 8440-2088 | easYgen-3500XT-P2 | check analog inputs | | |
LR20077 | AMG2S45B/BCEZHI1JNOQFQUR1R2SFT4VW | 8440-2088 | easYgen-3500XT-P2 | check analog inputs | | |
LR20091 | AMG2S45B/A2BDHI1JNR1SFTZT7V | 8440-2088 | easYgen-3500XT-P2 | check analog inputs | | |
LR20104 | AMG2S45B/A2BCDHI1JNQFQUR1SFVX | 8440-2281 | easYgen-3200XT-LITE | addional IKD1M evenually required | | |
LR20105 | AMG2S45B/N2PB | 8440-2082 | easYgen-3200XT | addional IKD1M evenually required | | |
LR20109 | AMG2S45B/A2HJPR1R2V | 8440-2281 | easYgen-3200XT-LITE | addional IKD1M evenually required | | |
LR20117 | AMG2S45B/CDHI1JNPQFR1R2SFT7VX | 8440-2088 | easYgen-3500XT-P2 | check analog inputs | | |
LR20140 | AMG2S45B/MGSN1 | 8440-2290 | easYgen-3500XT-P2-RENTAL | | | |
LR20141 | AMG2S45B/A2BCDHJNR1SFT7VX | 8440-2088 | easYgen-3500XT-P2 | check analog inputs | | |
LR20142 | AMG2S45B/VERSION HAGL | 8440-2088 | easYgen-3500XT-P2 | check analog inputs, keep in mind that protocols are not same | | |
LR20143 | AMG2S45B/VERSION HAGL-QF | 8440-2088 | easYgen-3500XT-P2 | check analog inputs, keep in mind that protocols are not same | | |
LR20144 | AMG2S45B/VERSION HAGL-C | 8440-2088 | easYgen-3500XT-P2 | check analog inputs, keep in mind that protocols are not same | | |
LR20155 | AMG2S45B/N1PB-SFT7 | 8440-2088 | easYgen-3500XT-P2 | check analog inputs | | |
LR20157 | AMG2S15B/DHJPR1SFT7V | 8440-2088 | easYgen-3500XT-P2 | check analog inputs | | |
LR20189 | AMG2S41B/GSS-A2DNOQFQUR1SFT7W | 8440-2088 | easYgen-3500XT-P2 | check analog inputs | | |
LR20190 | AMG2S45-H0018B/N2PB-A2QFQUSFVSW01XZE | 8440-2088 | easYgen-3500XT-P2 | check analog inputs | | |
LR20208 | AMG2S45B/BCDEZHI1JNPR1R2SFTZT7VW | 8440-2088 | easYgen-3500XT-P2 | check analog inputs | | |
LR20214 | AMG2S45B/N1PB-NQFSFT7X | 8440-2088 | easYgen-3500XT-P2 | check analog inputs | | |
LR20222 | AMG2S45B/A2CDI1NPR1R2SFT7WX | 8440-2088 | easYgen-3500XT-P2 | check analog inputs | | |
LR20235 | AMG2S45B/N1PB-QUSFT7 | 8440-2088 | easYgen-3500XT-P2 | check analog inputs | | |
LR20308 | AMG2S45B/SAM VERSION 1.25 | 8440-2088 | easYgen-3500XT-P2 | external AirFuelRatio AFR Control required | | |
LR20321 | AMG2A45B/A2BDJNQFR1R2SFT4V | 8440-2088 | easYgen-3500XT-P2 | check analog inputs | | |
LR20322 | AMG2S45B/N2PB-SC | 8440-2082 | easYgen-3200XT | addional IKD1M evenually required | | |
LR20323 | AMG2A45B/A2BDEZI1NQFR1R2SFSUT7TZXZS | 8440-2088 | easYgen-3500XT-P2 | check analog inputs | | |
LR20328 | AMG2S45B/A1CDEZHJNPQFQUR1R2SFT7VWX | 8440-2088 | easYgen-3500XT-P2 | check analog inputs | | |
LR20361 | AMG2S45B/N2PB-K01QF | 8440-2088 | easYgen-3500XT-P2 | check analog inputs, keep in mind that protocols are not same | | |
LR20362 | AMG2S45B/N2PB-A2 | 8440-2082 | easYgen-3200XT | addional IKD1M evenually required | | |
LR20368 | AMG2S45B/N1PB-A2QFQUSFT7X | 8440-2088 | easYgen-3500XT-P2 | check analog inputs, keep in mind that protocols are not same | | |
LR20383 | AMG2S45B/N1PB-SFT7QU | 8440-2088 | easYgen-3500XT-P2 | check analog inputs, keep in mind that protocols are not same | | |
LR20391 | AMG2S45B/N2PB-SFSC | 8440-2082 | easYgen-3200XT | addional IKD1M evenually required | | |
LR20392 | AMG2S45B/EWA5+BCDEZHI1JNPR1R2SFT7TZV | 8440-2088 | easYgen-3500XT-P2 | check analog inputs, keep in mind that protocols are not same | | |
LR20393 | AMG2S45B/N1PB-A2X | 8440-2082 | easYgen-3200XT | addional IKD1M evenually required | | |
LR20395 | AMG2S45B/SAM VERSION 4.25 | 8440-2088 | easYgen-3500XT-P2 | external AirFuelRatio AFR Control required | | |
LR20400 | AMG2S45B/N2PB-A2T7X | 8440-2088 | easYgen-3500XT-P2 | check analog inputs, keep in mind that protocols are not same | | |
LR20414 | AMG2S45B/N2PB-SFZS | 8440-2082 | easYgen-3200XT | addional IKD1M evenually required | | |
LR20425 | AMG2S45B/A2BDEZHI1IN20JNQFR1SFT7VWX | 8440-2088 | easYgen-3500XT-P2 | check analog inputs, keep in mind that protocols are not same | | |
LR20427 | AMG2S45B/N2PB-IN20QUT7 | 8440-2088 | easYgen-3500XT-P2 | check analog inputs, keep in mind that protocols are not same | | |
LR20439 | AMG2S15B/N2PB-A2QFQUSFT7X | 8440-2088 | easYgen-3500XT-P2 | check analog inputs, keep in mind that protocols are not same | | |
LR20441 | AMG2S45B/N2PB-IN20SBT7TZX | 8440-2088 | easYgen-3500XT-P2 | check analog inputs, keep in mind that protocols are not same | | |
LR20442 | AMG2S45B/N2PB-IN20T7TZX | 8440-2088 | easYgen-3500XT-P2 | check analog inputs, keep in mind that protocols are not same | | |
LR20468 | AMG2S45B/BCDEZHI1JNPR1R2SFT7TZVW | 8440-2088 | easYgen-3500XT-P2 | check analog inputs, keep in mind that protocols are not same | | |
LR20481 | AMG2S45B/N2PB-A2QFQUSFX | 8440-2082 | easYgen-3200XT | addional IKD1M evenually required | | |
LR20482 | AMG2S45B/N1PB-A2QFQUSFXZE | 8440-2082 | easYgen-3200XT | addional IKD1M evenually required | | |
LR20498 | AMG2S45B/N2PB-SFX | 8440-2082 | easYgen-3200XT | addional IKD1M evenually required | | |
LR20499 | AMG2S45B/A1BDEZE1HI3JLMNQFR1SFT7VWZA | 8440-2088 | easYgen-3500XT-P2 | check analog inputs, keep in mind that protocols are not same, LS-4 not supported by replacement | | |
LR20506 | AMG2S45-H0018B/N2PB-A2QFQUSFVSW01XZE | 8440-2290 | easYgen-3500XT-P2-RENTAL | not compatible with Synchon Remote Maintance box | | |
LR20517 | AMG2S45B/N1PB-QFQUSFT7X | 8440-2088 | easYgen-3500XT-P2 | check analog inputs, keep in mind that protocols are not same | | |
LR20536 | AMG2S45B/N2PB-QF | 8440-2082 | easYgen-3200XT | addional IKD1M evenually required | | |
LR20537 | AMG2S45B/N1PB-QFSFT7X | 8440-2088 | easYgen-3500XT-P2 | check analog inputs, keep in mind that protocols are not same | | |
LR20552 | AMG2S45-H0004B/N2PB | 8440-2082 | easYgen-3200XT | addional IKD1M evenually required | | |
LR20557 | AMG2S45B/N1PB-SF | 8440-2082 | easYgen-3200XT | addional IKD1M evenually required | | |
LR20561 | AMG2S15B/N2PB-QFQUSF | 8440-2082 | easYgen-3200XT | addional IKD1M evenually required | | |
LR20574 | AMG2S45B/N1PB-QFQUSFT7ZE | 8440-2088 | easYgen-3500XT-P2 | check analog inputs, keep in mind that protocols are not same | | |
LR20580 | AMG2S45B/N1PB-SFT7 | 8440-2088 | easYgen-3500XT-P2 | check analog inputs, keep in mind that protocols are not same | | |
LR20581 | AMG2S45B/N1PB-SFT7 | 8440-2088 | easYgen-3500XT-P2 | check analog inputs, keep in mind that protocols are not same | | |
LR20598 | AMG2A45B/A2BDEZI1NQFR1R2SFSUT7TZXZEZS | 8440-2088 | easYgen-3500XT-P2 | check analog inputs, keep in mind that protocols are not same | | |
LR20622 | AMG2S15B/N2PB-SFT7 | 8440-2088 | easYgen-3500XT-P2 | check analog inputs, keep in mind that protocols are not same | | |
LR20648 | AMG2S41B/N1PB-SFT7 | 8440-2088 | easYgen-3500XT-P2 | check analog inputs, keep in mind that protocols are not same | | |
LR20658 | AMG2S45B/A2BCDEZHI1JNQFQUR1R2SFT7VWOX | 8440-2088 | easYgen-3500XT-P2 | check analog inputs, keep in mind that protocols are not same | | |
LR20659 | AMG2S45B/N2PB-A2IN20SFT7X | 8440-2088 | easYgen-3500XT-P2 | check analog inputs, keep in mind that protocols are not same | | |
LR20668 | AMG2S45B/N1PB-A2QFQUSFXZE | 8440-2082 | easYgen-3200XT | addional IKD1M evenually required | | |
LR20669 | AMG2S45-H0018B/N2PB-A2IN20SFX | 8440-2082 | easYgen-3200XT | addional IKD1M evenually required | | |
LR20682 | AMG2S45B/N1PB-SFT7 | 8440-2088 | easYgen-3500XT-P2 | check analog inputs, keep in mind that protocols are not same | | |
LR20689 | AMG2S45B/N2PB-A2SF-DT | 8440-2082 | easYgen-3200XT | addional IKD1M evenually required | | |
LR20693 | AMG2S45B/N1PB-IN20QFQUYMS-ENGL | 8440-2290 | easYgen-3500XT-P2-RENTAL | not compatible with Synchon Remote Maintance box | | |
LR20697 | AMG2S45B/A1BDEZE1HI3JLMNQFR1SFT7VWZA | 8440-2088 | easYgen-3500XT-P2 | check analog inputs, keep in mind that protocols are not same, LS-4 not supported by replacement | | |
LR20698 | AMG2A45B/N1PB-QFSFT7 | 8440-2088 | easYgen-3500XT-P2 | check analog inputs, keep in mind that protocols are not same | | |
LR20709 | AMG2S45-H0004B/N2PB-ZE | 8440-2082 | easYgen-3200XT | addional IKD1M evenually required | | |
LR20711 | AMG2S45B/A2EVC1 | | | sorry, there is no direct replacement available | | |
LR20712 | AMG2S41B/N1PB-T7 | 8440-2088 | easYgen-3500XT-P2 | check analog inputs, keep in mind that protocols are not same | | |
LR20716 | AMG2S41B/N1PB-T7 | 8440-2088 | easYgen-3500XT-P2 | check analog inputs, keep in mind that protocols are not same | | |
LR20735 | AMG2S15B/N2PB-A2QFX | 8440-2082 | easYgen-3200XT | addional IKD1M evenually required | | |
LR20738 | AMG2S11-H0004B/N2PB-A2IN20SFT7X | 8440-2088 | easYgen-3500XT-P2 | check analog inputs, keep in mind that protocols are not same | | |
LR20746 | AMG2S41B/N2PB-SCSCMT7 | 8440-2088 | easYgen-3500XT-P2 | check analog inputs, keep in mind that protocols are not same | | |
LR20757 | AMG2S45B/N2PB-A2SFT7X | 8440-2088 | easYgen-3500XT-P2 | check analog inputs, keep in mind that protocols are not same | | |
LR20761 | AMG2S45B/N2PB-QFIN20 | 8440-2082 | easYgen-3200XT | addional IKD1M evenually required | | |
LR20779 | AMG2S45B/BCDEZHI1JNPR1R2SFSCSCMTZT7VW | 8440-2088 | easYgen-3500XT-P2 | check analog inputs, keep in mind that protocols are not same | | |
LR20782 | AMG2S45B/BCDEZHI1JNPR1R2SCSCMSFTZT7VW | 8440-2088 | easYgen-3500XT-P2 | check analog inputs, keep in mind that protocols are not same | | |
LR20786 | AMG2S45B/SAM VERSION 1.28 | 8440-2088 | easYgen-3500XT-P2 | check analog inputs, keep in mind that protocols are not same, external AirFuelRatio AFR Control required | | |
LR20810 | AMG2S11B/N2PB-T7 | 8440-2088 | easYgen-3500XT-P2 | check analog inputs, keep in mind that protocols are not same | | |
LR20829 | AMG2S45B/N2PB-SFT7 | 8440-2088 | easYgen-3500XT-P2 | check analog inputs, keep in mind that protocols are not same | | |
LR20833 | AMG2S45B/N2PB-K01QFT7 | 8440-2088 | easYgen-3500XT-P2 | check analog inputs, keep in mind that protocols are not same | | |
LR20837 | AMG2S45-H0004B/N2PB-T7SF | 8440-2088 | easYgen-3500XT-P2 | check analog inputs, keep in mind that protocols are not same | | |
LR20839 | AMG2S45B/N2PB-IN20QFSBT7TZZEX | 8440-2088 | easYgen-3500XT-P2 | check analog inputs, keep in mind that protocols are not same | | |
LR20852 | AMG2S45B/N1PB-SFT7-EWA003 | 8440-2088 | easYgen-3500XT-P2 | check analog inputs, keep in mind that protocols are not same | | |
LR20853 | AMG2S45B/N2PB-SFT7-EWA003 | 8440-2088 | easYgen-3500XT-P2 | check analog inputs, keep in mind that protocols are not same | | |
LR20854 | AMG2S45B/N2PB-SFT7YMS-EWA003 | 8440-2290 | easYgen-3500XT-P2-RENTAL | not compatible with Synchon Remote Maintance box | | |
LR20869 | AMG2S45B/N2PB-A2QFQUSFXZE | 8440-2082 | easYgen-3200XT | addional IKD1M evenually required | | |
LR20906 | AMG2S45B/N2PB-IN20QFSBT7TZ01ZEX | 8440-2088 | easYgen-3500XT-P2 | check analog inputs, keep in mind that protocols are not same | | |
LR20910 | AMG2S41B/A1DHI1JPQFR1SFT7VWXZEIN20 | 8440-2088 | easYgen-3500XT-P2 | check analog inputs, keep in mind that protocols are not same | | |
LR20911 | AMG2S41B/N2PB-A2SCSCMT7X | 8440-2088 | easYgen-3500XT-P2 | check analog inputs, keep in mind that protocols are not same | | |
LR20914 | AMG2S45B/N2PB-A2IN20QFQUSFSUT7TZZEZS | 8440-2088 | easYgen-3500XT-P2 | check analog inputs, keep in mind that protocols are not same | | |
LR20922 | AMG2S45B/N2PB-A2QF01QUSFX | 8440-2082 | easYgen-3200XT | addional IKD1M evenually required | | |
LR20930 | AMG2S45B/N2PB-A2T7X | 8440-2088 | easYgen-3500XT-P2 | check analog inputs, keep in mind that protocols are not same | | |
LR20931 | AMG2S45B/N2PB-SFXZE | 8440-2082 | easYgen-3200XT | addional IKD1M evenually required | | |
LR20933 | AMG2S45B/N2PB-T7 | 8440-2088 | easYgen-3500XT-P2 | check analog inputs, keep in mind that protocols are not same | | |
LR20940 | AMG2S45B/N2PB-A2SCM | 8440-2082 | easYgen-3200XT | addional IKD1M evenually required | | |
LR20941 | AMG2S45B/N2PB-A2SFX | 8440-2082 | easYgen-3200XT | addional IKD1M evenually required | | |
LR20967 | AMG2S11B/N2PB-A2SCSCM | 8440-2082 | easYgen-3200XT | addional IKD1M evenually required | | |
LR20973 | AMG2S45B/N2PB-A2QFSCMSFT7XZEZS | 8440-2088 | easYgen-3500XT-P2 | check analog inputs, keep in mind that protocols are not same | | |
LR20974 | AMG2S45B/N2PB-A2QFSFT7TZ01TZXZEZS | 8440-2088 | easYgen-3500XT-P2 | check analog inputs, keep in mind that protocols are not same | | |
LR20976 | AMG2A45B/N1PB-QFT7 | 8440-2088 | easYgen-3500XT-P2 | check analog inputs, keep in mind that protocols are not same | | |
LR20977 | AMG2S45B/N1PB-SFT7ZE | 8440-2088 | easYgen-3500XT-P2 | check analog inputs, keep in mind that protocols are not same | | |
LR20987 | AMG2S45B/N2PB-SFT7 | 8440-2088 | easYgen-3500XT-P2 | check analog inputs, keep in mind that protocols are not same | | |
LR20989 | AMG2S45B/N1PB-QFQUT4ZE | 8440-2088 | easYgen-3500XT-P2 | check analog inputs, keep in mind that protocols are not same | | |
LR20990 | AMG2S45B/N2PB-QFQUT7 | 8440-2088 | easYgen-3500XT-P2 | check analog inputs, keep in mind that protocols are not same | | |
LR20992 | AMG2S45-H0018B/N2PB-A2IN20X | 8440-2082 | easYgen-3200XT | addional IKD1M evenually required | | |
LR21000 | AMG2S45B/N2PB-IN20SFT7-EWA003 | 8440-2088 | easYgen-3500XT-P2 | check analog inputs, keep in mind that protocols are not same | | |
LR21010 | AMG2S45B/N2PB-T7 | 8440-2088 | easYgen-3500XT-P2 | check analog inputs, keep in mind that protocols are not same | | |
LR21018 | AMG2S45B/N2PB-T7 | 8440-2088 | easYgen-3500XT-P2 | check analog inputs, keep in mind that protocols are not same | | |
LR21022 | AMG2S45B/N1PB-SFZE | 8440-2082 | easYgen-3200XT | addional IKD1M evenually required | | |
LR21025 | AMG2S15B/SAM VERSION 5.XX | 8440-2088 | easYgen-3500XT-P2 | check analog inputs, keep in mind that protocols are not same, external AirFuelRatio AFR Control required | | |
LR21029 | AMG2S45B/N2PB-T7 | 8440-2088 | easYgen-3500XT-P2 | check analog inputs, keep in mind that protocols are not same | | |
LR21031 | AMG2S45B/N1PB | 8440-2082 | easYgen-3200XT | addional IKD1M evenually required | | |
LR21038 | AMG2S15B/N2PB-A2QFQUSBSFT7XZEZS | 8440-2088 | easYgen-3500XT-P2 | check analog inputs, keep in mind that protocols are not same | | |
LR21040 | AMG2S45B/N1PB-QFSFT7XZE | 8440-2088 | easYgen-3500XT-P2 | check analog inputs, keep in mind that protocols are not same | | |
LR21041 | AMG2S45B/BDHJR1SFSUT7TZV | 8440-2088 | easYgen-3500XT-P2 | check analog inputs, keep in mind that protocols are not same | | |
LR21052 | AMG2S45B/N1PB-IN20QFQUSFT4YMSZE | 8440-2290 | easYgen-3500XT-P2-RENTAL | not compatible with Synchon Remote Maintance box | | |
LR21055 | AMG2S45B/N1PB-QFSFT7ZEZS | 8440-2088 | easYgen-3500XT-P2 | check analog inputs, keep in mind that protocols are not same | | |
LR21056 | AMG2S45B/N2PB-SCSCM | 8440-2082 | easYgen-3200XT | addional IKD1M evenually required | | |
LR21069 | AMG2S41-H0018B/N1PB-A2IN20SFT7X | 8440-2088 | easYgen-3500XT-P2 | check analog inputs, keep in mind that protocols are not same | | |
LR21072 | AMG2S45B/N2PB-ZE | 8440-2082 | easYgen-3200XT | addional IKD1M evenually required | | |
LR21075 | AMG2S45B/N2PB-SFT7ZE | 8440-2088 | easYgen-3500XT-P2 | check analog inputs, keep in mind that protocols are not same | | |
LR21078 | AMG2S45B/A2BDEZE1HI3JLMNQFR1SFT7VWZA | 8440-2088 | easYgen-3500XT-P2 | check analog inputs, keep in mind that protocols are not same, LS-4 not supported by replacement | | |
LR21086 | AMG2S45B/N2PB-SEC400 | | | customized; no replacement | | |
LR21122 | AMG2S45B/N2PB-IN20T7TZTZ01QFXZE | 8440-2088 | easYgen-3500XT-P2 | check analog inputs, keep in mind that protocols are not same | | |
LR21123 | AMG2S45B/N1PB-YMSQF | 8440-2288 | easYgen-3500XT-P1-RENTAL | not compatible with Synchon Remote Maintance box | | |
LR21125 | AMG2S41B/N2PB-A2T7 | 8440-2088 | easYgen-3500XT-P2 | check analog inputs, keep in mind that protocols are not same | | |
LR21126 | AMG2S45B/N2PB-IN20T7TZTZ01QFXZESB | 8440-2088 | easYgen-3500XT-P2 | check analog inputs, keep in mind that protocols are not same | | |
LR21135 | AMG2S45B/N2PB-SEC400 | | | customized; no replacement | | |
LR21138 | AMG2S15B/DHJPQFR1SFT7V | 8440-2088 | easYgen-3500XT-P2 | check analog inputs, keep in mind that protocols are not same | | |
LR21160 | AMG2S45B/N2PB-T7 | 8440-2088 | easYgen-3500XT-P2 | check analog inputs, keep in mind that protocols are not same | | |
LR21161 | AMG2S41B/N1PB-T7SCSCM | 8440-2088 | easYgen-3500XT-P2 | check analog inputs, keep in mind that protocols are not same | | |
LR21232 | AMG2S45B/N2PB-A2QFQUSB03SFXZE | 8440-2088 | easYgen-3500XT-P2 | check analog inputs, keep in mind that protocols are not same, CAT CCM not supported in replacement | | |
LR21298 | AMG2S15B/N2PB-A2QFQUSFT7XZEZS | 8440-2088 | easYgen-3500XT-P2 | check analog inputs, keep in mind that protocols are not same | | |
LR21300 | AMG2S15B/N2PB-A2QFQUX | 8440-2082 | easYgen-3200XT | addional IKD1M evenually required | | |
LR21301 | AMG2S45B/N2PB-QU | 8440-2082 | easYgen-3200XT | addional IKD1M evenually required | | |
LR21310 | AMG2A45B/A1BDIN20JNR1SFT7VW | 8440-2088 | easYgen-3500XT-P2 | check analog inputs, keep in mind that protocols are not same | | |
LR21323 | AMG2S45B/A1DHI1JPQFR1SFT7VWXZEIN20 | 8440-2088 | easYgen-3500XT-P2 | check analog inputs, keep in mind that protocols are not same | | |
8440-1009 | AMG2S45/N2PB-SFIN20T7 | 8440-2088 | easYgen-3500XT-P2 | check analog inputs, keep in mind that protocols are not same | | |
8440-1010 | AMG2S45/N1PB-SFIN20T7 | 8440-2088 | easYgen-3500XT-P2 | check analog inputs, keep in mind that protocols are not same | | |
8440-1035 | AMG2S45B/N2PB-A2QFSFT7X | 8440-2088 | easYgen-3500XT-P2 | check analog inputs, keep in mind that protocols are not same | | |
8440-1036 | AMG2S45B/N1PB-A2SFT7 | 8440-2088 | easYgen-3500XT-P2 | check analog inputs, keep in mind that protocols are not same | | |
8440-1043 | AMG2S41B/N2PB-SCSFT7 | 8440-2088 | easYgen-3500XT-P2 | check analog inputs, keep in mind that protocols are not same | | |
8440-1048 | AMG2S45B/N2PB-A2SFT7ZE | 8440-2088 | easYgen-3500XT-P2 | check analog inputs, keep in mind that protocols are not same | | |
8440-1049 | AMG2S45B/N1PB-A2IN20SFT7X | 8440-2088 | easYgen-3500XT-P2 | check analog inputs, keep in mind that protocols are not same | | |
8440-1050 | AMG2S45B/N2PB | 8440-2082 | easYgen-3200XT | addional IKD1M evenually required | | |
8440-1056 | AMG2S45B/N1PB-L4SFZEZS | 8440-2085 | easYgen-3500XT-P1 | check analog inputs, keep in mind that protocols are not same, LS-4 not supported by replacement | | |
8440-1057 | AMG2S45B/N2PB-SFT7TZX-EWA003 | 8440-2088 | easYgen-3500XT-P2 | check analog inputs, keep in mind that protocols are not same | | |
8440-1065 | AMG2S45B/N1PB-SCSCMSFT7X | 8440-2088 | easYgen-3500XT-P2 | check analog inputs, keep in mind that protocols are not same | | |
8440-1066 | AMG2S45B/N2PB-SCSCM01SFT7TZTZ01X-EWA003 | 8440-2088 | easYgen-3500XT-P2 | check analog inputs, keep in mind that protocols are not same, MDEC not supported in replacement | | |
8440-1067 | AMG2S45B/N2PB-QUSCSCMSFXZEZS | 8440-2082 | easYgen-3200XT | addional IKD1M evenually required | | |
8440-1068 | AMG2S45B/N2PB-SC02SFT7TZX-EWA003 | 8440-2088 | easYgen-3500XT-P2 | check analog inputs, keep in mind that protocols are not same, MDEC not supported in replacement | | |
8440-1087 | AMG2S45B/N1PB-A2QUSFT7 | 8440-2088 | easYgen-3500XT-P2 | check analog inputs, keep in mind that protocols are not same, MDEC not supported in replacement | | |
8440-1089 | AMG2S15B/N2PB-X | 8440-2082 | easYgen-3200XT | addional IKD1M evenually required | | |
8440-1091 | AMG2S45B/N2PB-A2QFQUX | 8440-2082 | easYgen-3200XT | addional IKD1M evenually required | | |
8440-1094 | AMG2S45B/N2PB-QFZS | 8440-2082 | easYgen-3200XT | addional IKD1M evenually required | | |
8440-1095 | AMG2S45B/N2PB-A2T7X | 8440-2088 | easYgen-3500XT-P2 | check analog inputs, keep in mind that protocols are not same, MDEC not supported in replacement | | |
8440-1097 | AMG2S45B/N2PB-A2SC02SFT7XZE | 8440-2088 | easYgen-3500XT-P2 | check analog inputs, keep in mind that protocols are not same, MDEC not supported in replacement | | |
8440-1108 | AMG2S45B/N2PB-SCSCM01SFT7 | 8440-2088 | easYgen-3500XT-P2 | check analog inputs, keep in mind that protocols are not same, MDEC not supported in replacement | | |
8440-1110 | AMG2S45B/GSS-A2DNOQUR1SFT7W | 8440-2088 | easYgen-3500XT-P2 | check analog inputs, keep in mind that protocols are not same, MDEC not supported in replacement | | |
8440-1130 | AMG2S45B/N1PB-QFQUSFZEZS | 8440-2082 | easYgen-3200XT | addional IKD1M evenually required | | |
8440-1178 | AMG2S15B/N2PB-SFT7 | 8440-2088 | easYgen-3500XT-P2 | check analog inputs, keep in mind that protocols are not same, MDEC not supported in replacement | | |
8440-1179 | AMG2S41B/N2PB-A2SCSCMSF | 8440-2082 | easYgen-3200XT | addional IKD1M evenually required | | |
8440-1190 | AMG2S41-H0018B/N2PB-A2IN20SFT7X | 8440-2088 | easYgen-3500XT-P2 | check analog inputs, keep in mind that protocols are not same, MDEC not supported in replacement | | |
8440-1197 | AMG2S45B/N2PB-SFT7X | 8440-2088 | easYgen-3500XT-P2 | check analog inputs, keep in mind that protocols are not same, MDEC not supported in replacement | | |
8440-1198 | AMG2S45B/N2PB-SFT7TZXYMS-EWA003 | 8440-2290 | easYgen-3500XT-P2-RENTAL | not compatible with Synchon Remote Maintance box | | |
8440-1211 | AMG2S45B/N1PB-SFT7 | 8440-2088 | easYgen-3500XT-P2 | check analog inputs, keep in mind that protocols are not same | | |
8440-1212 | AMG2S41B/N2PB-A2SCSCM | X | | easYgen3200XT but without MDEC support | | |
8440-1263 | AMG2S41B/N2PB-D01 | X | | easYgen3200XT | | |
8440-1268 | AMG2S45B/N1PB-SCSCM01SFT7TZTZ01X-EWA003 | 8440-2088 | easYgen-3500XT-P2 | check analog inputs, keep in mind that protocols are not same | | |
8440-1269 | AMG2S45B/N2PB-SEC400 | | | sorry, there is no direct replacement available | | |
8440-1275 | AMG2S45B/N1PB-A2IN20L4SFT7X | 8440-2088 | easYgen-3500XT-P2 | check analog inputs, keep in mind that protocols are not same, LS-4 not supported by replacement | | |
8440-1273 | AMG2S45B/N1PB-FGW01IN20QSFT4YMS01ZE | 8440-2290 | easYgen-3500XT-P2-RENTAL | not compatible with Synchon Remote Maintance box | | |
8440-1277 | AMG2S41B/N2PB-SUT8 | 8440-2088 | easYgen-3500XT-P2 | check analog inputs, keep in mind that protocols are not same | | |
8440-1281 | AMG2S45B/N1PB-L4QSF | 8440-2085 | easYgen-3500XT-P1 | check analog inputs, keep in mind that protocols are not same, LS-4 not supported by replacement | | |
8440-1292 | AMG2S45-H0018B/N2PB-A2QUSFVSW01XZE | 8440-2290 | easYgen-3500XT-P2-RENTAL | not compatible with Synchon Remote Maintance box | | |
8440-1294 | AMG2S45B/N1PB-QFSBT7TZ02ZEZS | 8440-2088 | easYgen-3500XT-P2 | check analog inputs, keep in mind that protocols are not same | | |
8440-1299 | AMG2S45B/N2PB-K01QSFT7 | 8440-2088 | easYgen-3500XT-P2 | check analog inputs, keep in mind that protocols are not same | | |
8440-1305 | AMG2S45B/N1PB-T7 | 8440-2088 | easYgen-3500XT-P2 | check analog inputs, keep in mind that protocols are not same | | |
8440-1307 | AMG2S45-H0018B/N2PB-A2SFT7 | 8440-2088 | easYgen-3500XT-P2 | check analog inputs, keep in mind that protocols are not same | | |
8440-1308 | AMG2S41B/N2PB-QSC02T7X | 8440-2088 | easYgen-3500XT-P2 | check analog inputs, keep in mind that protocols are not same | | |
8440-1309 | AMG2S41B/GSS-ML-A2DNOQFQUR1SFT7W | 8440-2088 | easYgen-3500XT-P2 | check analog inputs, keep in mind that protocols are not same | | |
8440-1313 | AMG2S45B/N1PB-D02QSFT7 | 8440-2088 | easYgen-3500XT-P2 | check analog inputs, keep in mind that protocols are not same | | |
8440-1317 | AMG2S45B/N2PB-SCSCMT7 | 8440-2088 | easYgen-3500XT-P2 | check analog inputs, keep in mind that protocols are not same | | |
8440-1318 | AMG2S45-H0018B/N2PB-A2QSFT7XZE | 8440-2088 | easYgen-3500XT-P2 | check analog inputs, keep in mind that protocols are not same | | |
8440-1336 | AMG2S45B/N2PB-A2SC02SFT7 | 8440-2088 | easYgen-3500XT-P2 | check analog inputs, keep in mind that protocols are not same | | |
8440-1337 | AMG2S41B/N2PB-A2SC02SFT7 | 8440-2088 | easYgen-3500XT-P2 | check analog inputs, keep in mind that protocols are not same | | |
8440-1338 | AMG2S45B/N1PB-SC02SFT7TZX-EWA003 | 8440-2088 | easYgen-3500XT-P2 | check analog inputs, keep in mind that protocols are not same | | |
8440-1341 | AMG2S45B/A2EVC1 | | | sorry, there is no direct replacement available | | |
8440-1343 | AMG2S45-H0018B/N2PB-A2SFVSW01XZE | 8440-2290 | easYgen-3500XT-P2-RENTAL | not compatible with Synchon Remote Maintance box | | |
8440-1345 | AMG2S11B/N2PB-A2QSC06SFT705 | 8440-2088 | easYgen-3500XT-P2 | check analog inputs, keep in mind that protocols are not same | | |
8440-1349 | AMG2S45B/N2PB-A2QSF | 8440-2082 | easYgen-3200XT | addional IKD1M evenually required | | |
8440-1356 | AMG2S15B/N2PB-A2QSCSCMSFT7X | 8440-2088 | easYgen-3500XT-P2 | check analog inputs, keep in mind that protocols are not same | | |
8440-1357 | AMG2S45B/N2PB-A2SFT7 | 8440-2088 | easYgen-3500XT-P2 | check analog inputs, keep in mind that protocols are not same | | |
8440-1370 | AMG2S11B/N2PB+A2QSCSCMSFT7X | 8440-2088 | easYgen-3500XT-P2 | check analog inputs, keep in mind that protocols are not same, MDEC not supported in replacement | | |
8440-1372 | AMG2S45B/N1PB-A2SFT7TZX-EWA003 | 8440-2088 | easYgen-3500XT-P2 | check analog inputs, keep in mind that protocols are not same | | |
8440-1375 | AMG2S45B/N2PB-SC02SF | 8440-2082 | easYgen-3200XT | addional IKD1M evenually required | | |
8440-1376 | AMG2S45B/N1PB-D04IM01PM03QFSBT7TZ02ZEZS | 8440-2088 | easYgen-3500XT-P2 | check analog inputs, keep in mind that protocols are not same | | |
8440-1379 | AMG2S45B/N1PB-A2L4SFT7 | 8440-2088 | easYgen-3500XT-P2 | check analog inputs, keep in mind that protocols are not same, LS-4 not supported by replacement | | |
8440-1381 | AMG2S45B/N1PB-L4SFT7 | 8440-2088 | easYgen-3500XT-P2 | check analog inputs, keep in mind that protocols are not same, LS-4 not supported by replacement | | |
8440-1386 | AMG2S45B/N2PB-A2QSC04SFT7VSW01XZE | 8440-2290 | easYgen-3500XT-P2-RENTAL | not compatible with Synchon Remote Maintance box | | |
8440-1387 | AMG2S15B/GSS-A2DNOQFQUR1SFT7W | 8440-2088 | easYgen-3500XT-P2 | check analog inputs, keep in mind that protocols are not same | | |
8440-1391 | AMG2S11B/N2PB-A2SFT7X | 8440-2088 | easYgen-3500XT-P2 | check analog inputs, keep in mind that protocols are not same | | |
8440-1393 | AMG2S45B/N1PB-A2SFT7X | 8440-2088 | easYgen-3500XT-P2 | check analog inputs, keep in mind that protocols are not same | | |
8440-1400 | AMG2S41B/N2PB-SCSCM01SFT7X | 8440-2088 | easYgen-3500XT-P2 | check analog inputs, keep in mind that protocols are not same | | |
8440-1402 | AMG2S45B/N1PB-QSCSCM01SF | 8440-2082 | easYgen-3200XT | addional IKD1M evenually required | | |
8440-1408 | AMG2S45B/N2PB-A2SC02SFT7 | 8440-2088 | easYgen-3500XT-P2 | check analog inputs, keep in mind that protocols are not same | | |
8440-1415 | AMG2S45B/N1PB-QSCSCM01SFT7 | 8440-2088 | easYgen-3500XT-P2 | check analog inputs, keep in mind that protocols are not same | | |
8440-1416 | AMG2S45B/N1PB-A2D05L4SFT7XZE | 8440-2088 | easYgen-3500XT-P2 | check analog inputs, keep in mind that protocols are not same, LS-4 not supported by replacement | | |
8440-1425 | AMG2S45B/N2PB-A2QSCSCM01SFT7XZEZS | 8440-2088 | easYgen-3500XT-P2 | check analog inputs, keep in mind that protocols are not same | | |
8440-1440 | AMG2S45B/N1PB-L4QSC02SFT7 | 8440-2088 | easYgen-3500XT-P2 | check analog inputs, keep in mind that protocols are not same, LS-4 not supported by replacement | | |
8440-1441 | AMG2S41B/N2PB-A2SCSCMSFT7ZS | 8440-2088 | easYgen-3500XT-P2 | check analog inputs, keep in mind that protocols are not same | | |
8440-1461 | AMG2S11B/N1PB-A2SC02SFT7 | 8440-2088 | easYgen-3500XT-P2 | check analog inputs, keep in mind that protocols are not same | | |
8440-1462 | AMG2S45B/N1PB-A2QSC04SFT7VSW01XZE | 8440-2290 | easYgen-3500XT-P2-RENTAL | not compatible with Synchon Remote Maintance box | | |
8440-1511 | AMG2S15-H0022B/N1PB-A2QSBCCM02SFT4ZE | 8440-2088 | easYgen-3500XT-P2 | check analog inputs, keep in mind that protocols are not same, CAT CCM not supported in replacement | | |
8440-1516 | AMG2S45B/A2EEA1 | | | sorry, there is no direct replacement available | | |
8440-1523 | AMG2S45B/N1PB-D05QSCSCM01SFSF02 | 8440-2088 | easYgen-3500XT-P2 | check analog inputs, keep in mind that protocols are not same, MDEC not supported in replacement | | |
8440-1524 | AMG2S45B/N1PB-QSFT1YMS | 8440-2290 | easYgen-3500XT-P2-RENTAL | not compatible with Synchon Remote Maintance box | | |
8440-1533 | AMG2S41-H0018/N1PB-L4SFT7 | 8440-2088 | easYgen-3500XT-P2 | check analog inputs, keep in mind that protocols are not same, LS-4 not supported by replacement | | |
8440-1536 | AMG2S45B/N2PB-K01QSC04SFT701 | 8440-2088 | easYgen-3500XT-P2 | check analog inputs, keep in mind that protocols are not same | | |
8440-1538 | AMG2S41B/N2PB+A2SC10SFT702 | 8440-2088 | easYgen-3500XT-P2 | check analog inputs, keep in mind that protocols are not same | | |
8440-1539 | AMG2S45B/GSS-A2DNOQFQUR1SFT7W | 8440-2088 | easYgen-3500XT-P2 | check analog inputs, keep in mind that protocols are not same | | |
8440-1616 | AMG2S45B/N2PB+A2K01M03QSFT717ZE | 8440-2088 | easYgen-3500XT-P2 | check analog inputs, keep in mind that protocols are not same | | |
8440-1655 | AMG2S45B/MGSN1 | 8440-2290 | easYgen-3500XT-P2-RENTAL | not compatible with Synchon Remote Maintance box | | |
8440-1659 | AMG2S45B/N2PB-A2K01QSFT701ZE | 8440-2088 | easYgen-3500XT-P2 | check analog inputs, keep in mind that protocols are not same | | |
8440-1670 | AMG2S45B/A1DHI1IN20JK15PQFR1SFT7VWXZE | 8440-2088 | easYgen-3500XT-P2 | check analog inputs, keep in mind that protocols are not same | | |
8440-1678 | AMG2S45B/N1PB+D08QSC10SFT710ZS | 8440-2088 | easYgen-3500XT-P2 | check analog inputs, keep in mind that protocols are not same | | |
8440-1687 | AMG2S45B/N2PB+QSC06SFT701ZEZS | 8440-2088 | easYgen-3500XT-P2 | check analog inputs, keep in mind that protocols are not same | | |
8440-1690 | AMG2S45B/N2PB+A2K01QSFT701ZE | 8440-2088 | easYgen-3500XT-P2 | check analog inputs, keep in mind that protocols are not same | | |
8440-1691 | AMG2S41B/N2PB-SC06SFT712 | 8440-2088 | easYgen-3500XT-P2 | check analog inputs, keep in mind that protocols are not same | | |
8440-1692 | AMG2S45B/N2PB+A2QSC10SFT701ZEZS | 8440-2088 | easYgen-3500XT-P2 | check analog inputs, keep in mind that protocols are not same | | |
8440-1697 | AMG2S41B/N2PB+A2SC10SFT707ZS | 8440-2088 | easYgen-3500XT-P2 | check analog inputs, keep in mind that protocols are not same | | |
8440-1721 | AMG2A45B/N1PB+A2K01QSFT701ZE | 8440-2088 | easYgen-3500XT-P2 | check analog inputs, keep in mind that protocols are not same | | |
8440-1727 | AMG2S45B/A2SVA1 | | | customized; no replacement | | |
8440-1762 | AMG2S11B/N2PB+A2SC10SFT707ZS | 8440-2088 | easYgen-3500XT-P2 | check analog inputs, keep in mind that protocols are not same, CAT CCM not supported in replacement | | |
8440-1792 | AMG2S45B/N2PB+A2K01QSFT717ZE | 8440-2088 | easYgen-3500XT-P2 | check analog inputs, keep in mind that protocols are not same, CAT CCM not supported in replacement | | |
8440-1793 | AMG2S45B/K21 | 8440-2082 | easYgen-3200XT | addional IKD1M evenually required | | |
8440-1854 | AMG2S45B/N2PB+A2K01M03QSFT717ZE | 8440-2088 | easYgen-3500XT-P2 | check analog inputs, keep in mind that protocols are not same, CAT CCM not supported in replacement | | |
8406-121 | EGCP-2 LOW VOLTAGE | 8440-2083 | easYgen-3200XT | EGCP-2 and 3200XT can do kW&KVAr sharing with a LSG Loadshare Gateway between | | |
8406-140 | EGCP-2 HIGH VOLTAGE | 8440-2084 | easYgen-3200XT | EGCP-2 and 3200XT can do kW&KVAr sharing with a LSG Loadshare Gateway between | | |
8406-141 | EGCP-2 LOW VOLTAGE | 8440-2085 | easYgen-3200XT | EGCP-2 and 3200XT can do kW&KVAr sharing with a LSG Loadshare Gateway between | | |
8406-130 | EGCP-2 HIGH VOLTAGE | 8440-2086 | easYgen-3200XT | EGCP-2 and 3200XT can do kW&KVAr sharing with a LSG Loadshare Gateway between | | |
8406-131 | EGCP-2 LOW VOLTAGE | 8440-2087 | easYgen-3200XT | EGCP-2 and 3200XT can do kW&KVAr sharing with a LSG Loadshare Gateway between | | |
8406-102 | EGCP-2 | 8440-2088 | easYgen-3200XT | EGCP-2 and 3200XT can do kW&KVAr sharing with a LSG Loadshare Gateway between | | |
8406-112 | EGCP-2 LOW VOLTAGE | 8440-2089 | easYgen-3200XT | EGCP-2 and 3200XT can do kW&KVAr sharing with a LSG Loadshare Gateway between | | |
8406-115 | EGCP-2 LOW VOLTAGE | 8440-2090 | easYgen-3200XT | EGCP-2 and 3200XT can do kW&KVAr sharing with a LSG Loadshare Gateway between | | |
8406-116 | EGCP-2 HIGH VOLTAGE | 8440-2091 | easYgen-3200XT | EGCP-2 and 3200XT can do kW&KVAr sharing with a LSG Loadshare Gateway between | | |
8440-1750 | easYgen-1500-55B | 8440-1809 | easYgen-1500-55B | | | |
8440-1751 | easYgen-1500-51B | 8440-1810 | easYgen-1500-51B | | | |
8440-1826 | easYgen-1500-51B | 8440-1810 | easYgen-1500-51B | | | |
8440-1324 | easYgen-1500-55B | 8440-1809 | easYgen-1500-55B | | | |
8440-1330 | easYgen-1500-55B | 8440-1809 | easYgen-1500-55B | | | |
8440-1331 | easYgen-1500-51B | 8440-1810 | easYgen-1500-51B | | | |
8440-1424 | easYgen-1500-55B | 8440-1809 | easYgen-1500-55B | | | |
8440-1544 | easYgen-1500-55B/BLUE | 8440-1809 | easYgen-1500-55B | | | |
8440-1545 | easYgen-1500-51B/BLUE | 8440-1810 | easYgen-1500-51B | | | |
8440-1637 | easYgen-1500-55B/CH | 8440-1809 | easYgen-1500-55B | | | |
8440-1638 | easYgen-1500-51B/CH | 8440-1810 | easYgen-1500-51B | | | |
8440-1639 | easYgen-1500-51B/JP | 8440-1810 | easYgen-1500-51B | | | |
8440-1640 | easYgen-1500-55B/JP | 8440-1809 | easYgen-1500-55B | | | |
8440-1641 | easYgen-1500-51B/CH+BLUE | 8440-1810 | easYgen-1500-51B | | | |
8440-1642 | easYgen-1500-55B/CH+BLUE | 8440-1809 | easYgen-1500-55B | | | |
8440-1643 | easYgen-1500-51B/JP+BLUE | 8440-1810 | easYgen-1500-51B | | | |
8440-1644 | easYgen-1500-55B/JP+BLUE | 8440-1809 | easYgen-1500-55B | | | |
8440-1742 | easYgen-1500-55B/K18 | 8440-1809 | easYgen-1500-55B | | | |
8440-1750 | easYgen-1500-55B | 8440-1809 | easYgen-1500-55B | | | |
8440-1751 | easYgen-1500-51B | 8440-1810 | easYgen-1500-51B | | | |
8440-1752 | easYgen-1500-55B/M02 | 8440-1809 | easYgen-1500-55B | | | |
8440-1757 | easYgen-1500-55B | 8440-1809 | easYgen-1500-55B | | | |
8440-1809 | easYgen-1500-55B | 8440-1809 | easYgen-1500-55B | | | |
8440-1814 | easYgen-1500-55B | 8440-1809 | easYgen-1500-55B | | | |
8440-1810 | easYgen-1500-51B | 8440-1810 | easYgen-1500-51B | | | |
8440-1820 | easYgen-1500-55B | 8440-1809 | easYgen-1500-55B | | | |
8440-1821 | easYgen-1500-55B | 8440-1809 | easYgen-1500-55B | | | |
8440-1822 | easYgen-1500-55B/K22 | 8440-1809 | easYgen-1500-55B | | | |
8440-1826 | easYgen-1500-51B | 8440-1810 | easYgen-1500-51B | | | |
8440-1837 | easYgen-1500-55B | 8440-1809 | easYgen-1500-55B | | | |
8440-1865 | easYgen-1500-55B | 8440-1809 | easYgen-1500-55B | | | |
8440-1875 | easYgen-1500-55B | 8440-1809 | easYgen-1500-55B | | | |
8440-1879 | easYgen-1500-55B | 8440-1809 | easYgen-1500-55B | | | |
8440-1880 | easYgen-1500-55B/LP01 | 8440-1809 | easYgen-1500-55B | | | |
8440-1883 | easYgen-1500-55B/LP02 | 8440-1809 | easYgen-1500-55B | | | |
8440-1881 | easYgen-1500-55B | 8440-1809 | easYgen-1500-55B | | | |
8440-1886 | easYgen-1500-55B/LP03 | 8440-1809 | easYgen-1500-55B | | | |
8440-1899 | easYgen-1500-55B/LP02 | 8440-1809 | easYgen-1500-55B | | | |
8440-1900 | easYgen-1500-51B/LP02 | 8440-1810 | easYgen-1500-51B | | | |
8440-1901 | easYgen-1500-55B/M05 | 8440-1809 | easYgen-1500-55B | | | |
8440-1903 | easYgen-1500-55B/K26 | 8440-1809 | easYgen-1500-55B | | | |
8440-1906 | easYgen-1500-55B/EMC | 8440-1809 | easYgen-1500-55B | | | |
8440-1920 | easYgen-1500-55B/LP01 | 8440-1809 | easYgen-1500-55B | | | |
8440-1938 | easYgen-1500-51B/LP01 | 8440-1810 | easYgen-1500-51B | | | |
8440-1942 | easYgen-1500-55B | 8440-1809 | easYgen-1500-55B | | | |
8440-1944 | easYgen-1500-55B/K29 | 8440-1809 | easYgen-1500-55B | | | |
8440-1976 | easYgen-1500-51B/LP02 | 8440-1810 | easYgen-1500-51B | | | |
8440-1975 | easYgen-1500-55B/LP02 | 8440-1809 | easYgen-1500-55B | | | |
8440-2024 | easYgen-1500-55B/LP02 | 8440-1809 | easYgen-1500-55B | | | |
8440-2022 | easYgen-1500-55B/LP01 | 8440-1809 | easYgen-1500-55B | | | |
8440-2023 | easYgen-1500-55B/LP01 | 8440-1809 | easYgen-1500-55B | | | |
8440-2092 | easYgen-1500-55B/LP03 | 8440-1809 | easYgen-1500-55B | | | |
8440-2196 | easYgen-1500-55B | 8440-1809 | easYgen-1500-55B | | | |
8440-1324 | easYgen-1500-51B | 8440-1810 | easYgen-1500-51B | | | |
8440-1742 | easYgen-1500-55B/K18 (REV G) | 8440-1809 | easYgen-1500-55B | | | |
8440-1814 | easYgen-1500-55B | 8440-1809 | easYgen-1500-55B | | | |
8440-1886 | easYgen-1500-55B/LP03 | 8440-1809 | easYgen-1500-55B | | | |
8440-1942 | easYgen-1500-55B | 8440-1809 | easYgen-1500-55B | | | |
LR20017 | SG2D-R-24-M | | consider EPG, APECS4000, DPG speed controls | | | |
LR20341 | SG2D-12/24 | | consider EPG, APECS4000, DPG speed controls | | | |
LR20486 | SG2D-R-12-M | | consider EPG, APECS4000, DPG speed controls | | | |
LR20797 | SG2D-T-LOVS | | was mainly used to control FloTech | | | |
LR20808 | SG2D-T-HOVS | | consider EPG, APECS4000, DPG speed controls | | | |
LR20834 | SG2D-T-LOS | | was mainly used to control FloTech | | | |
LR20835 | SG2D-T-HOS | | consider EPG, APECS4000, DPG speed controls | | | |
LR20979 | SG2D-T-HOVM | | consider EPG, APECS4000, DPG speed controls | | | |
LR21102 | SG2D-T-HOM | | consider EPG, APECS4000, DPG speed controls | | | |
LR21294 | SG2D-T-HOVM | | consider EPG, APECS4000, DPG speed controls | | | |
5448-904 | SG2D-T-HOVS | | consider EPG, APECS4000, DPG speed controls | | | |
5448-905 | SG2D-T-LOVS | | was mainly used to control FloTech | | | |
5448-911 | SG2D-T-HOS | | consider EPG, APECS4000, DPG speed controls | | | |
5448-912 | SG2D-T-LOS | | was mainly used to control FloTech | | | |
8443-1001 | SG2D-T-HOVM | | consider EPG, APECS4000, DPG speed controls | | | |
8443-1002 | SG2D-T-LOVM | | was mainly used to control FloTech | | | |
8443-1003 | SG2D-T-HOVS | | consider EPG, APECS4000, DPG speed controls | | | |
8443-1004 | SG2D-T-LOVS | | was mainly used to control FloTech | | | |
8443-1005 | SG2D-T-HOS | | consider EPG, APECS4000, DPG speed controls | | | |
8443-1006 | SG2D-T-HOM | | consider EPG, APECS4000, DPG speed controls | | | |
8443-1007 | SG2D-R-24-S | | consider EPG, APECS4000, DPG speed controls | | | |
LR20175 | ST2M/A3E1SC | | Lambda 1 Regulator | | | |
LR20226 | ST2M/A3L | | Lambda 1 Regulator | | | |
LR20234 | ST2M/A3 | | Lambda 1 Regulator | | | |
LR20562 | ST2S/A3 | | Lambda 1 Regulator | | | |
LR20749 | ST2M/A1A3A4E1SC | | Lambda 1 Regulator | | | |
LR21299 | ST2M/A3E1L | | Lambda 1 Regulator | | | |
8442-1003 | ST3M/V3 | | UEGO Leanburn Regulator | | | |
8442-1004 | ST3S/A1E1 | | UEGO Leanburn Regulator | | | |
8442-1005 | ST3M/V1 | | UEGO Leanburn Regulator | | | |
8442-1006 | ST3M/A3E1 | | UEGO Leanburn Regulator | | | |
8442-1019 | ST3M/A01 | | UEGO Leanburn Regulator | | | |
LR20064 | QFR/M120-0 | 8444-1161 | easYprotec-1470-1 | 24VDC powered | | |
LR20180 | QFR/M120-2 | 8444-1161 | easYprotec-1470-1 | 24VDC powered | | |
LR20453 | QFR/M110-0 | 8444-1160 | easYprotec-1410-1 | 24VDC powered | | |
LR20465 | QFR/M126-0 | 8444-1161 | easYprotec-1470-1 | 24VDC powered | | |
LR20567 | QFR/M121-2 | 8444-1161 | easYprotec-1470-1 | 24VDC powered | | |
8441-1039 | QFR/M120-1 | 8444-1161 | easYprotec-1470-1 | 24VDC powered | | |
8441-1100 | QFR/M120-3 | 8444-1161 | easYprotec-1470-1 | 24VDC powered | | |
LR20006 | FRT120-2 | 8444-1161 | easYprotec-1470-1 | 24VDC powered | | |
LR20504 | FRT210-1R | 8444-1160 | easYprotec-1410-1 | 24VDC powered | | |
LR20728 | FRT110-1 | 8444-1160 | easYprotec-1410-1 | 24VDC powered | | |
LR21312 | FRT120-1 | 8444-1161 | easYprotec-1470-1 | 24VDC powered | | |
LR21313 | FRT110-8 | 8444-1160 | easYprotec-1410-1 | 24VDC powered | | |
LR21314 | FRT110-9 | 8444-1160 | easYprotec-1410-1 | 24VDC powered | | |
LR21315 | FRT120-8 | 8444-1161 | easYprotec-1470-1 | 24VDC powered | | |
LR21316 | FRT120-9 | 8444-1161 | easYprotec-1470-1 | 24VDC powered | | |
LR21317 | FRT110-0 | 8444-1160 | easYprotec-1410-1 | 24VDC powered | | |
LR21318 | FRT110-2 | 8444-1160 | easYprotec-1410-1 | 24VDC powered | | |
LR21319 | FRT120-0 | 8444-1161 | easYprotec-1470-1 | 24VDC powered | | |
LR21320 | FRT220-0 | 8444-1161 | easYprotec-1470-1 | 24VDC powered | | |
LR21321 | FRT210-2 | 8444-1160 | easYprotec-1410-1 | 24VDC powered | | |
LR21322 | FRT220-2 | 8444-1161 | easYprotec-1470-1 | 24VDC powered | | |
LR20047 | UUR/M440-2 | 8444-1161 | easYprotec-1470-1 | 24VDC powered | | |
LR20048 | UUR/M416-2 | 8444-1160 | easYprotec-1410-1 | 24VDC powered | | |
LR20203 | UUR/M313-0 | 8444-1160 | easYprotec-1410-1 | 24VDC powered | | |
LR20380 | UUR/M310-2 | 8444-1160 | easYprotec-1410-1 | 24VDC powered | | |
LR20636 | UUR/M340-0 | 8444-1161 | easYprotec-1470-1 | 24VDC powered | | |
LR20691 | UUR/M340-7A | 8444-1161 | easYprotec-1470-1 | 24VDC powered | | |
LR20727 | UUR/M310-3NS | 8444-1160 | easYprotec-1410-1 | 24VDC powered | | |
LR20803 | UUR/M310-0 | 8444-1160 | easYprotec-1410-1 | 24VDC powered | | |
LR20820 | UUR/M340-3NS | 8444-1161 | easYprotec-1470-1 | 24VDC powered | | |
LR20867 | UUR/M441-0 | 8444-1161 | easYprotec-1470-1 | 24VDC powered | | |
LR21014 | UUR/M310-3NSR | 8444-1160 | easYprotec-1410-1 | 24VDC powered | | |
LR21118 | UUR/M340-3NSR | 8444-1161 | easYprotec-1470-1 | 24VDC powered | | |
LR21141 | UUR/M410-7 | 8444-1160 | easYprotec-1410-1 | 24VDC powered | | |
8441-1053 | UUR/M440-0 | 8444-1161 | easYprotec-1470-1 | 24VDC powered | | |
8441-1069 | UUR/M216-3 | 8444-1160 | easYprotec-1410-1 | 24VDC powered | | |
8441-1117 | UUR/M316-0 | 8444-1160 | easYprotec-1410-1 | 24VDC powered | | |
8270-821 | SPM DIGITAL | 8440-2167 or 8440-2176 | consider SPM-D10-2YB | please check the measuring inputs 100 V or 400 V to determine the replacement item number | | |
8270-839 | SPM DIGITAL | 8440-2167 or 8440-2176 | consider SPM-D10-2YB | please check the measuring inputs 100 V or 400 V to determine the replacement item number | | |
8270-933 | SPM DIGITAL | 8440-2167 or 8440-2176 | consider SPM-D10-2YB | please check the measuring inputs 100 V or 400 V to determine the replacement item number | | |
8271-120 | SPM DIGITAL | 8440-2167 or 8440-2176 | consider SPM-D10-2YB | please check the measuring inputs 100 V or 400 V to determine the replacement item number | | |
8271-152 | SPM DIGITAL | 8440-2167 or 8440-2176 | consider SPM-D10-2YB | please check the measuring inputs 100 V or 400 V to determine the replacement item number | | |
8271-153 | SPM DIGITAL | 8440-2167 or 8440-2176 | consider SPM-D10-2YB | please check the measuring inputs 100 V or 400 V to determine the replacement item number | | |
8271-383 | SPM DIGITAL | 8440-2167 or 8440-2176 | consider SPM-D10-2YB | please check the measuring inputs 100 V or 400 V to determine the replacement item number | | |
8271-452 | SPM DIGITAL | 8440-2167 or 8440-2176 | consider SPM-D10-2YB | please check the measuring inputs 100 V or 400 V to determine the replacement item number | | |
8271-607 | SPM DIGITAL | 8440-2167 or 8440-2176 | consider SPM-D10-2YB | please check the measuring inputs 100 V or 400 V to determine the replacement item number | | |
8271-663 | SPM DIGITAL | 8440-2167 or 8440-2176 | consider SPM-D10-2YB | please check the measuring inputs 100 V or 400 V to determine the replacement item number | | |
8271-682 | SPM DIGITAL | 8440-2167 or 8440-2176 | consider SPM-D10-2YB | please check the measuring inputs 100 V or 400 V to determine the replacement item number | | |
8271-745 | SPM DIGITAL | 8440-2167 or 8440-2176 | consider SPM-D10-2YB | please check the measuring inputs 100 V or 400 V to determine the replacement item number | | |
8272-110 | SPM-A STD W/O VM | 9907-028 | SPM-A STD NON VOLTAGE MATCH (EMC) UL ASSEMBLY no ROHS | | | |
8272-190 | SPM (FAST DYNS) | 9907-029 | SPM-A STD 1% VOLTAGE MATCHING (EMC) ASSEMBLY UL no ROHS | | | |
8272-383 | SPM (FAST DYNS) | 9907-029 | SPM-A STD 1% VOLTAGE MATCHING (EMC) ASSEMBLY UL no ROHS | | | |
8272-385 | SPM (FAST DYNS) | 9907-029 | SPM-A STD 1% VOLTAGE MATCHING (EMC) ASSEMBLY UL no ROHS | | | |
8272-494 | SPM (FAST DYNS) | 9907-029 | SPM-A STD 1% VOLTAGE MATCHING (EMC) ASSEMBLY UL no ROHS | | | |
9900-160 | SPM DIGITAL | 9907-029 | SPM-A STD 1% VOLTAGE MATCHING (EMC) ASSEMBLY UL no ROHS | | | |
9900-348 | SPM DIGITAL | 9907-029 | SPM-A STD 1% VOLTAGE MATCHING (EMC) ASSEMBLY UL no ROHS | | | |
9904-083 | SPM (FAST) (UL) | 9907-029 | SPM-A STD 1% VOLTAGE MATCHING (EMC) ASSEMBLY UL no ROHS | | | |
9904-119 | SPM (FAST) (UL) | 9907-029 | SPM-A STD 1% VOLTAGE MATCHING (EMC) ASSEMBLY UL no ROHS | | | |
9904-121 | SPM (FAST) (UL) | 9907-029 | SPM-A STD 1% VOLTAGE MATCHING (EMC) ASSEMBLY UL no ROHS | 9907-028 | | |
9904-122 | SPM (FAST) (UL) | 9907-029 | SPM-A STD 1% VOLTAGE MATCHING (EMC) ASSEMBLY UL no ROHS | 9907-029 | | |
9905-001 | SPM-A STD W/O VM | 9907-028 | SPM-A STD NON VOLTAGE MATCH (EMC) UL ASSEMBLY no ROHS | 9905-003 | | |
9905-002 | SPM-A (VM5) | 9907-029 | SPM-A STD 1% VOLTAGE MATCHING (EMC) ASSEMBLY UL no ROHS | 9906-121 | | |
9905-004 | SPM-A (W/0 VM) | 9907-028 | SPM-A STD NON VOLTAGE MATCH (EMC) UL ASSEMBLY no ROHS | | | |
9905-005 | SPM-A | 9907-029 | SPM-A STD 1% VOLTAGE MATCHING (EMC) ASSEMBLY UL no ROHS | | | |
9905-006 | SPM-A (VM5) | 9905-003 | SPM-A 5% VOLTAGE MATCHING no ROHS | | | |
9905-009 | SPM-A (VM) | 9907-029 | SPM-A STD 1% VOLTAGE MATCHING (EMC) ASSEMBLY UL no ROHS | | | |
9905-107 | SPM-A | 9907-029 | SPM-A STD 1% VOLTAGE MATCHING (EMC) ASSEMBLY UL no ROHS | | | |
9907-492 | SPM-A 5% VOLTAGE MATCHING EMC ASSEMBLY | 9905-003 | SPM-A 5% VOLTAGE MATCHING no ROHS | | | |
8239-001 | DSM (STANDARD) no VoltMatch | 9907-028 | SPM-A STD NON VOLTAGE MATCH (EMC) UL ASSEMBLY no ROHS | DSM had raise&lower f+/- contacts, SPM-D2 culd be as well an option | | |
8239-002 | DSM (VOLT MATCH 1%) | 9907-029 | SPM-A STD 1% VOLTAGE MATCHING (EMC) ASSEMBLY UL no ROHS | DSM had raise&lower U+/- & f+/- contacts, SPM-D2 could be as well an option | | |
8239-013 | DSM (VOLT MATCH 5%) | 9907-029 | SPM-A STD 1% VOLTAGE MATCHING (EMC) ASSEMBLY UL no ROHS | DSM had raise&lower U+/- & f+/- contacts, SPM-D2 could be as well an option | | |
8239-017 | DSM (STANDARD no UL no VoltMatch) | 9907-028 | SPM-A STD NON VOLTAGE MATCH (EMC) UL ASSEMBLY no ROHS | DSM had raise&lower f+/- contacts, SPM-D2 culd be as well an option | | |
8239-018 | DSM ( VoltMatch 1%) | 9907-029 | SPM-A STD 1% VOLTAGE MATCHING (EMC) ASSEMBLY UL no ROHS | DSM had raise&lower U+/- & f+/- contacts, SPM-D2 could be as well an option | | |
9905-203 | DSM (STANDARD) no VoltMatch | 9907-028 | SPM-A STD NON VOLTAGE MATCH (EMC) UL ASSEMBLY no ROHS | DSM had raise&lower f+/- contacts, SPM-D2 culd be as well an option | | |
9905-204 | DSM (VOLT MATCH 1%) | 9907-029 | SPM-A STD 1% VOLTAGE MATCHING (EMC) ASSEMBLY UL no ROHS | DSM had raise&lower U+/- & f+/- contacts, SPM-D2 could be as well an option | | |
9905-346 | DSM (VOLT MATCH 1%) | 9907-029 | SPM-A STD 1% VOLTAGE MATCHING (EMC) ASSEMBLY UL no ROHS | DSM had raise&lower U+/- & f+/- contacts, SPM-D2 could be as well an option | | |
9905-347 | DSM (STANDARD) no VoltMatch | 9907-028 | SPM-A STD NON VOLTAGE MATCH (EMC) UL ASSEMBLY no ROHS | DSM had raise&lower f+/- contacts, SPM-D2 culd be as well an option | | |
8239-069 | DSM (VOLT MATCH 5%) | 9907-029 | SPM-A STD 1% VOLTAGE MATCHING (EMC) ASSEMBLY UL no ROHS | DSM had raise&lower U+/- & f+/- contacts, SPM-D2 could be as well an option | | |
8440-1878 | DSLC-2-5 | 8440-2299 | DSLC-2XT | Ethernet Communication - no LON ! | | |
8440-1978 | DSLC-2-1 | 8440-2299 | DSLC-2XT | Ethernet Communication - no LON ! | | |
8440-1877 | MSLC-2-5 | 8440-2298 | MSLC-2XT | Ethernet Communication - no LON ! | | |
8440-1977 | MSLC-2-1 | 8440-2298 | MSLC-2XT | Ethernet Communication - no LON ! | | |
DYN2-94025 | BC ITEM-POW-R-CON CONTROLLER | 8440-2082 | easYgen-3200XT | | | |
DYN2-94026 | BC ITEM-POW-R-CON,NO KEYPAD | 8440-2082 | easYgen-3200XT | | | |
DYNA-29900 | KIT-POW-R-CON | 8440-2082 | easYgen-3200XT | | | |
DYN2-94025-004 | CONTROL-POW-R-CON KEYPAD | 8440-2082 | easYgen-3200XT | | | |
DYN2-94026-001 | BC ITEM-POW-R-CON,NO KEYPAD | 8440-2082 | easYgen-3200XT | | | |
DYN2-94026-002 | BC ITEM-POW-R-CON,NO KEYPAD | 8440-2082 | easYgen-3200XT | | | |
DYN2-94026-003 | BC ITEM-POW-R-CON,NO KEYPAD | 8440-2082 | easYgen-3200XT | | | |
DYN2-94026-004 | CONTROL-POW-R-CON NO KEYPAD | 8440-2082 | easYgen-3200XT | | | |
DYN2-94026-822 | BC ITEM-POW-R-CON,NO KEYPAD | 8440-2082 | easYgen-3200XT | | | |
DYN2-94026-823 | BC ITEM-POW-R-CON,NO KEYPAD | 8440-2082 | easYgen-3200XT | | | |
DYNA-29900-001 | KIT-POW-R-CON | 8440-2082 | easYgen-3200XT | | | |
DYNA-29900-003 | KIT-POW-R-CON | 8440-2082 | easYgen-3200XT | | | |
DYNA-29900-004 | KIT-POW-R-CON | 8440-2082 | easYgen-3200XT | | | |
DH94025-814-000 | BC ITEM-POW-R-CON CONTROLLER DYN2-94025-814-0-00 | 8440-2082 | easYgen-3200XT | | | |
DH94025-815-000 | BC ITEM-POW-R-CON CONTROLLER DYN2-94025-815-0-00 | 8440-2082 | easYgen-3200XT | | | |
DYN2-94025-814-0-00 | BC ITEM-POW-R-CON CONTROLLER DYN2-94025-814-0-00 | 8440-2082 | easYgen-3200XT | | | |
DYN2-94025-815-0-00 | BC ITEM-POW-R-CON CONTROLLER DYN2-94025-815-0-00 | 8440-2082 | easYgen-3200XT | | | |
8273-101 | | 8273-1011 | 2301E - ENGINE LSSC, 24VDC INPUT, ORDINARY LOCATION | | | |
8273-138 | | 8273-1011 | 2301E - ENGINE LSSC, 24VDC INPUT, ORDINARY LOCATION | | | |
8273-140 | | 8273-1011 | 2301E - ENGINE LSSC, 24VDC INPUT, ORDINARY LOCATION | | | |
8273-501 | | 8273-1011 | 2301E - ENGINE LSSC, 24VDC INPUT, ORDINARY LOCATION | | | |
8273-505 | | 8273-1011 | 2301E - ENGINE LSSC, 24VDC INPUT, ORDINARY LOCATION | | | |
8273-1003 | | 8273-1011 | 2301E - ENGINE LSSC, 24VDC INPUT, ORDINARY LOCATION | | | |
8273-135 | | 8273-1012 | 2301E - ENGINE LSSC, 24VDC INPUT, HAZARDOUS LOCATION | | | |
8273-139 | | 8273-1012 | 2301E - ENGINE LSSC, 24VDC INPUT, HAZARDOUS LOCATION | | | |
8273-141 | | 8273-1012 | 2301E - ENGINE LSSC, 24VDC INPUT, HAZARDOUS LOCATION | | | |
8273-503 | | 8273-1012 | 2301E - ENGINE LSSC, 24VDC INPUT, HAZARDOUS LOCATION | | | |
8273-507 | | 8273-1012 | 2301E - ENGINE LSSC, 24VDC INPUT, HAZARDOUS LOCATION | | | |
8273-1000 | | 8273-1012 | 2301E - ENGINE LSSC, 24VDC INPUT, HAZARDOUS LOCATION | | | |
8273-128 | | 8273-1013 | 2301E-ST - STEAM TURBINE LSSC, 24VDC INPUT, ORDINARY LOCATION | | | |
8273-136 | | 8273-1014 | 2301E-ST - STEAM TURBINE LSSC, 24VDC INPUT, HAZARDOUS LOCATION | | | |
8273-137 | | 8273-1014 | 2301E-ST - STEAM TURBINE LSSC, 24VDC INPUT, HAZARDOUS LOCATION | | | |
8273-127 | | none for hazardous location | | | | |
8273-1002 | | none for hazardous location | | | | |
2300-059 | | | | | | |
8272-854 | | | | | | |
5448-880 | GCP-1210B/X | 8440-2255 | easYgen-1800 | | | |
5448-881 | GCP-1210B | 8440-2255 | easYgen-1800 | | | |
5448-882 | GCP-1115B | 8440-2254 | easYgen-800 | | | |
8440-1015 | GCP-1240B | 8440-2255 | easYgen-1800 | | | |
8440-1037 | GCP-1145B/T2 | 8440-2254 | easYgen-800 | | | |
LR20701 | GCP-1210B/X | 8440-2255 | easYgen-1800 | | | |
LR20798 | GCP-1111B | 8440-2254 | easYgen-800 | | | |
LR20805 | GCP-1115B | 8440-2254 | easYgen-800 | | | |
LR20889 | GCP-1210B | 8440-2255 | easYgen-1800 | | | |
LR21103 | GCP-1240B | 8440-2255 | easYgen-1800 | | | |
8406-000 | GCP-1, 12VDC, 240VAC ASSEMBLY | 8440-2082 | easYgen-3200XT | Loadshare Gateway LSG required, if n+1 gensets | | |
8406-001 | GCP-1, 24VDC, 240VAC ASSEMBLY | 8440-2082 | easYgen-3200XT | Loadshare Gateway LSG required, if n+1 gensets | | |
8406-002 | GCP-1, 12VDC, 240VAC ASSEMBLY W/SOFTWARE | 8440-2082 | easYgen-3200XT | Loadshare Gateway LSG required, if n+1 gensets | | |
8406-002.EXP | GCP-1, 12VDC, 240VAC ASSEMBLY W/SOFTWARE | 8440-2082 | easYgen-3200XT | Loadshare Gateway LSG required, if n+1 gensets | | |
8406-003 | GCP-1, 24VDC, 240VAC ASSEMBLY W/SOFTWARE | 8440-2082 | easYgen-3200XT | Loadshare Gateway LSG required, if n+1 gensets | | |
8406-003.EXP | GCP-1, 24VDC, 240VAC ASSEMBLY W/SOFTWARE | 8440-2082 | easYgen-3200XT | Loadshare Gateway LSG required, if n+1 gensets | | |
8406-003.TEST | GCP-1, 24VDC, 240VAC ASSEMBLY W/SOFTWARE | 8440-2082 | easYgen-3200XT | Loadshare Gateway LSG required, if n+1 gensets | | |
8406-004 | GCP-1, 12VDC, 277VAC ASSEMBLY | 8440-2082 | easYgen-3200XT | Loadshare Gateway LSG required, if n+1 gensets | | |
8406-005 | GCP-1, 12VDC, 277VAC ASSEMBLY W/SOFTWARE | 8440-2082 | easYgen-3200XT | Loadshare Gateway LSG required, if n+1 gensets | | |
8406-006 | GCP-1, 24VDC, 277VAC ASSEMBLY | 8440-2082 | easYgen-3200XT | Loadshare Gateway LSG required, if n+1 gensets | | |
8406-007 | GCP-1, 24VDC, 277VAC ASSEMBLY W/SOFTWARE | 8440-2082 | easYgen-3200XT | Loadshare Gateway LSG required, if n+1 gensets | | |
8406-008 | GCP-1, 12VDC, 120VAC ASSEMBLY | 8440-2082 | easYgen-3200XT | Loadshare Gateway LSG required, if n+1 gensets | | |
8406-009 | GCP-1, 12VDC, 120VAC ASSEMBLY W/SOFTWARE | 8440-2082 | easYgen-3200XT | Loadshare Gateway LSG required, if n+1 gensets | | |
8406-010 | GCP-1, 24VDC, 120VAC ASSEMBLY | 8440-2082 | easYgen-3200XT | Loadshare Gateway LSG required, if n+1 gensets | | |
8406-011 | GCP-1, 24VDC, 120VAC ASSEMBLY W/SOFTWARE | 8440-2082 | easYgen-3200XT | Loadshare Gateway LSG required, if n+1 gensets | | |
8406-011.EXP | GCP-1, 24VDC, 120VAC ASSEMBLY W/SOFTWARE | 8440-2082 | easYgen-3200XT | Loadshare Gateway LSG required, if n+1 gensets | | |
8406-012 | GCP-1, 12VDC, 70VAC ASSEMBLY | 8440-2082 | easYgen-3200XT | Loadshare Gateway LSG required, if n+1 gensets | | |
8406-013 | GCP-1, 12VDC, 70VAC ASSEMBLY W/SOFTWARE | 8440-2082 | easYgen-3200XT | Loadshare Gateway LSG required, if n+1 gensets | | |
8406-013.EXP | GCP-1, 12VDC, 70VAC ASSEMBLY W/SOFTWARE | 8440-2082 | easYgen-3200XT | Loadshare Gateway LSG required, if n+1 gensets | | |
8406-014 | GCP-1, 24VDC, 70VAC ASSEMBLY | 8440-2082 | easYgen-3200XT | Loadshare Gateway LSG required, if n+1 gensets | | |
8406-015 | GCP-1, 24VDC, 70VAC ASSEMBLY W/SOFTWARE | 8440-2082 | easYgen-3200XT | Loadshare Gateway LSG required, if n+1 gensets | | |
8406-015.EXP | GCP-1, 24VDC, 70VAC ASSEMBLY W/SOFTWARE | 8440-2082 | easYgen-3200XT | Loadshare Gateway LSG required, if n+1 gensets | | |
LR20404 | AMG4S40B/NEB | 8440-2255 | easYgen-1800 | | | |
LR20405 | AMG4S45B/IEB | 8440-2254 | easYgen-800 | | | |
LR20487 | AMG4S45B/IEB | 8440-2254 | easYgen-800 | | | |
LR20579 | AMG4S40B/NEB-T2 | 8440-2255 | easYgen-1800 | | | |
LR20715 | AMG4S40B/NEB | 8440-2255 | easYgen-1800 | | | |
LR20753 | AMG4S45B/IEB-T2 | 8440-2254 | easYgen-800 | | | |
LR20760 | AMG4S40B/NEB-T2 | 8440-2255 | easYgen-1800 | | | |
LR20926 | AMG4S45B/IEB-T2 | 8440-2254 | easYgen-800 | | | |
LR20927 | AMG4S15B/IEB-T2 | 8440-2254 | easYgen-800 | | | |
LR20947 | AMG4S45B/IEB | 8440-2254 | easYgen-800 | | | |
LR21033 | AMG4S41B/IEB | 8440-2254 | easYgen-800 | | | |
LR21067 | AMG4S45B/IEB-T2 | 8440-2254 | easYgen-800 | | | |
8440-1120 | AMG4S45B/IEB-K07T2 | 8440-2254 | easYgen-800 | | | |
8440-1319 | AMG4S40B/NEB-T2 | 8440-2255 | easYgen-1800 | | | |
8446-1030 | RP-3000 - customer specific | 8446-1051 | ANNUNCIATOR - RP-3200-P2 | Please pay attention to flash the right software! A software compatability matrix with old easYgen3000 is in the manual and in the attachment of the linked support article. Please contact support for customer specific information, once you know the software versions of the different devices. | | |
8445-1005 | PCK4-SW RS232/LDP | 8445-1046 | ESEPRO | no replacement | | |
8445-1006 | PCK4-MW RS485 Modbus | 8445-1046 | ESEPRO | ProCon X GCP-MG-Gateway | | |
8445-1007 | PCK4-CW Modem | 8445-1046 | ESEPRO | no replacement | | |
8445-1008 | PCK4-PW ProfibusDP | 8445-1046 | ESEPRO | Protocol is not completely identical to PCM, PCL, MPU2 | | |
8440-1618 | PCN411B | 8440-2178 | LS-521-1 | Different CAN bus telegramm! LS5 not compatible with GCP-31 | | |
8440-1619 | PCN415B | 8440-2150 | LS-521-5 | Different CAN bus telegramm! LS5 not compatible with GCP-31 | | |
8440-1620 | PCN441B | 8440-2178 | LS-521-1 | Different CAN bus telegramm! LS5 not compatible with GCP-31 | | |
8440-1621 | PCN445B | 8440-2150 | LS-521-5 | Different CAN bus telegramm! LS5 not compatible with GCP-31 | | |
8440-1869 | SPM-D10B/PSY4-F-D | 8440-2170 | SPM-D2-10B/PSY5-FU-D | | | |
8440-1870 | SPM-D10B/PSY4-FU-D | 8440-2170 | SPM-D2-10B/PSY5-FU-D | | | |
8440-1871 | SPM-D10B/PSY5-FU-D | 8440-2170 | SPM-D2-10B/PSY5-FU-D | | | |
8440-1872 | SPM-D10B/PSY5-FU-A | 8440-2170 | SPM-D2-10B/PSY5-FU-D | use additional external electronic DI/AO Motorpoti | | |
8440-1873 | SPM-D10B/PSY5-FU-D-W | 8440-2173 | SPM-D2-10B/PSY5-FU-D-W | | | |
8440-1874 | SPM-D10B/PSY5-FU-A-W | 8440-2173 | SPM-D2-10B/PSY5-FU-D-W | use additional external electronic DI/AO Motorpoti | | |
8440-1058 | MFR2S45B/PSV-A2T2SFSF01 | 8440-2308 | easYgen-3100XT-P1-K57 | this K57 easYgen has same Sf01 CAN bus | | |
8440-1409 | MFR2S45B/A2CD06D09HI1I4JK24MMBPR1SFSF01T2VZ | 8440-2308 | easYgen-3100XT-P1-K57 | this K57 easYgen has same Sf01 CAN bus | | |
8440-1546 | MFR2S45B/A2CDD06D09HI1I4JK24MMBPR1SFSF01T2VZ | 8440-2308 | easYgen-3100XT-P1-K57 | this K57 easYgen has same Sf01 CAN bus | | |
8440-1660 | MFR2A45B/PSV+A2MMBSFSF01T2 | 8440-2308 | easYgen-3100XT-P1-K57 | this K57 easYgen has same Sf01 CAN bus | | |
8440-1815 | MFR2S11B/A2CD06D09HI1I4JK24MMBPR1SFSF01T2VZ | 8440-2308 | easYgen-3100XT-P1-K57 | this K57 easYgen has same Sf01 CAN bus | | |
8440-1852 | MFR2S11B/A2CDD06D09HI1I4JK24MMBPR1SFSF01T2VZ | 8440-2308 | easYgen-3100XT-P1-K57 | this K57 easYgen has same Sf01 CAN bus | | |
8440-2230 | EASYGEN-3500XT-P1-K51 | 8440-2085 | EASYGEN-3500XT-P1 | K51 was the GroupController support | | |
8441-1120 | MFR1371M/DQ3RSU08UV | 8444-1115 | MFR300-71M/SU08 | replacement with same Su08 protocol | | |
8441-1073 | MFR1311M-RSU03UV | 8444-1089 | MFR300-11M | Firmware upgrade 5418-6859-A required | | |
LR20158 | GW4B/PROFIBUS | 8445-1046 | ESEPRO | | | |
LR20174 | GW4M/PROFIBUS | 8445-1046 | ESEPRO | | | |
LR20480 | GW4B/PROFIBUS | 8445-1046 | ESEPRO | | | |
LR21116 | GW4B/PROFIBUS | 8445-1046 | ESEPRO | | | |
8445-1003 | GW4M/PROFIBUS | 8445-1046 | ESEPRO | | | |
8445-1011 | GW4B/PROFIBUS | 8445-1046 | ESEPRO | | | |
LR20115 | MFR1205B/50-51GN | | Ground fault measured via current transformer | contact SEG Electronics for MRI3 | | |
LR20116 | MFR1205M/IS | in easYgen-3000XT included | Overcurrent time + earth-fault protection calculated | contact SEG Electronics for MRI3 | | |
LR20148 | MFR1201M/IS | in easYgen-3000XT included | Overcurrent time + earth-fault protection calculated | contact SEG Electronics for MRI3 | | |
LR20313 | MFR1201M/IVIZR | | Earth-fault monitoring (displacement voltage) | contact SEG Electronics for MRI3 | | |
LR20474 | MFR1201M/IKN | | Earth-fault current time protection measured, wide range power supply | contact SEG Electronics for MRI3 | | |
LR20492 | MFR1201-H0001M/IZIZ01N | in easYgen-3000XT included | Independent overcurrent time protection | contact SEG Electronics for MRI3 | | |
LR20532 | MFR1201B/ISN | in easYgen-3000XT included | Overcurrent time + earth-fault protection calculated, wide range power supply | contact SEG Electronics for MRI3 | | |
LR20548 | MFR1205B/IZR | in easYgen-3000XT included | Independent overcurrent time protection | contact SEG Electronics for MRI3 | | |
LR20550 | MFR1211M/IKIVR | | Earth-fault current time protection measured, Earth-fault monitoring (displacement voltage) | contact SEG Electronics for MRI3 | | |
LR20625 | MFR1205M/IZN | in easYgen-3000XT included | Independent overcurrent time protection, wide range power supply | contact SEG Electronics for MRI3 | | |
LR20641 | MFR1201B/IZR | in easYgen-3000XT included | Independent overcurrent time protection | contact SEG Electronics for MRI3 | | |
LR20811 | MFR1205B/CP | in easYgen-3000XT included | Independent time-overcurrent,Ground fault calculated | contact SEG Electronics for MRI3 | | |
LR21013 | MFR1211B/IKIVR | | Earth-fault monitoring (displacement voltage), Earth-fault monitoring (displacement voltage) measured | contact SEG Electronics for MRI3 | | |
LR21120 | MFR1205B/CP | in easYgen-3000XT included | Independent time-overcurrent,Ground fault calculated | contact SEG Electronics for MRI3 | | |
LR21129 | MFR1201B/IZIV | | Independent overcurrent time protection, Earth-fault monitoring (displacement voltage) | contact SEG Electronics for MRI3 | | |
LR21134 | MFR1205B/IZSU | in easYgen-3000XT included | Independent overcurrent time protection, ProfibusDP | contact SEG Electronics for MRI3 | | |
LR21157 | MFR1201B/IZ | in easYgen-3000XT included | Independent overcurrent time protection | contact SEG Electronics for MRI3 | | |
8441-1001 | MFR1201B/ISIVSU | in easYgen-3000XT included | Overcurrent time + earth-fault protection calculated,Earth-fault monitoring (displacement voltage), ProfibusDP | contact SEG Electronics for MRI3 | | |
8441-1007 | MFR1210B/IVIKR | | Earth-fault monitoring (displacement voltage), Earth-fault monitoring (displacement voltage) measured | contact SEG Electronics for MRI3 | | |
8441-1021 | MFR1215M/IVIZR | | Earth-fault monitoring (displacement voltage),Independent overcurrent time protection | contact SEG Electronics for MRI3 | | |
8441-1031 | MFR1205B/CP | in easYgen-3000XT included | Independent time-overcurrent,Ground fault calculated | contact SEG Electronics for MRI3 | | |
8441-1078 | MFR1205B/IS | in easYgen-3000XT included | Overcurrent time + earth-fault protection | contact SEG Electronics for MRI3 | | |
8441-1079 | MFR1205M/50-51GN | | Ground fault measured via current transformer | contact SEG Electronics for MRI3 | | |
8441-1080 | MFR1205B/ISSU | in easYgen-3000XT included | Overcurrent time + earth-fault protection | contact SEG Electronics for MRI3 | | |
8441-1093 | MFR1211B/IVIZR | | Earth-fault monitoring (displacement voltage),Independent overcurrent time protection | contact SEG Electronics for MRI3 | | |
8441-1121 | MFR1210B/IV | | Earth-fault monitoring (displacement voltage) | contact SEG Electronics for MRI3 | | |
8440-1028 | SPM-D2141B/PSVX | 8440-2317 | LS-6XT-P2 | LS-6XT-P2 configured for active synchronization, consider 8446-1071 easYview HMI Display | | |
LR20010 | ESDR405TB | | | contact SEG Electronics for MRDT4-2A0AA | | |
LR20069 | ESDR405TB | | | contact SEG Electronics for MRDT4-2A0AA | | |
LR20145 | ESDR405TM | | | contact SEG Electronics for MRDT4-2A0AA | | |
LR20150 | ESDR401M | | | contact SEG Electronics for MRDT4-2A0AA | | |
LR20154 | ESDR405B | | | contact SEG Electronics for MRDT4-2A0AA | | |
LR20231 | ESDR405TM | | | contact SEG Electronics for MRDT4-2A0AA | | |
LR20312 | ESDR401TM | | | contact SEG Electronics for MRDT4-2A0AA | | |
LR20342 | ESDR401TB | | | contact SEG Electronics for MRDT4-2A0AA | | |
LR20459 | ESDR401B | | | contact SEG Electronics for MRDT4-2A0AA | | |
LR20472 | ESDR401TM | | | contact SEG Electronics for MRDT4-2A0AA | | |
LR20535 | ESDR405B | | | contact SEG Electronics for MRDT4-2A0AA | | |
LR20590 | ESDR405M | | | contact SEG Electronics for MRDT4-2A0AA | | |
LR20616 | ESDR401TM | | | contact SEG Electronics for MRDT4-2A0AA | | |
LR20617 | ESDR401B | | | contact SEG Electronics for MRDT4-2A0AA | | |
LR20632 | ESDR4T-H0007M | | | contact SEG Electronics for MRDT4-2A0AA | | |
LR20799 | ESDR405TB | | | contact SEG Electronics for MRDT4-2A0AA | | |
LR21044 | ESDR405M | | | contact SEG Electronics for MRDT4-2A0AA | | |
8441-1016 | ESDR401TB | | | contact SEG Electronics for MRDT4-2A0AA | | |
8441-1105 | ESDR401M | | | contact SEG Electronics for MRDT4-2A0AA | | |
8441-1150 | ESDR405TB/N | | | contact SEG Electronics for MRDT4-2A0AA | | |
8441-1154 | ESDR405TB/N | | | contact SEG Electronics for MRDT4-2A0AA | | |
8441-1158 | ESDR401TB/N | | | contact SEG Electronics for MRDT4-2A0AA | | |